5
BAK Thermoplastic Welding Technology AG
CHANGE OF NOZZLES AND REFLECTORS
Allow the tool to cool down before changing
nozzles/reflectors or use only combination pliers.
Do not touch the hot nozzle/reflector and make sure to put it
only on a heat resistant surface, because of fire hazard.
The nozzles/reflectors are easily pushed on to the tapered
element housing (7) and are secured by fastening the screw
on the clamp.
TECHNICAL DATA
Technical Data
ErOn BL
Voltage
V
230
120
Frequency
Hz
50 / 60
Power consumption
W
2300
2700
3400
Temperature
°C
20 – 650 stepless controlled
Max. air flow
l/min
600
Noise level (EN ISO
11203)
dB(A)
ca. 3000
Dimensions
mm (L x
W x H)
320 x 94, handle 64
Weight with 5 m
cable
kg
1.5 with 3m cord
Protection class
IP20
Conformity symbol
Protection type I
Electrical safety
double insulated
MAINTENANCE
Airfilter (5) should be cleaned with a brush.
Check power supply cord (1) and plug for any possible
electrical or mechanical damage.
Should the mains cable of the tool be damaged, it must be
immediately exchanged by the supplier, his customer service
or another qualified person to prevent danger.