background image

 

 

 

BA RoofOn V30 R16 12_2012 GB mit CE BAK.doc 

 

 

SCOPE OF DELIVERY

 

 

Content of package: 

 

1 Automatic welding machine type RoofOn 

 

1 Guide handle 

 

1 Starting plate 

 

1 Operating manual 

 
 

SICHERHEIT

 

 

 

 
Danger of life

 when opening the device as live components and connections are exposed. 

Unplug the device before opening it. 
 

 

Danger  of  fire  and  explosion

 

if  the  device  is  used  incorrectly.  Demonstrate  the  necessary 

caution  when  using  the  welding  machine  near  combustible  materials.  Never  use  the  device  in 
inflammable areas. 

 

 
!!! Danger of burns !!! 

Do not touch the hot air device when it is still hot. Let the device cool down. 
 

 

 

 

Connect the device to a 

socket with protective earth conductor

. Any interruption of the 

protective earth conductor within or outside the device is dangerous! Only use extension cables 
with protective earth conductor and a minimum diameter of 2.5 mm². 

 

The 

voltage rating

 stated on the nameplate must correspond to the mains voltage. 

Maintain the maximal allowed impedance Z

max

 = 0.301 Ω + j 0.188 Ω. 

Consult your local electricity supply board if necessary. 

 

 

For  personal  protection,  the  device  must  be  connected  to  a 

residual  current  circuit  breaker

 

before using it on construction sites. 
 

 

 

Do  not  leave  the  device  unobserved.

 

Hot  air  radiation  of  the  hot  air  device  may  ignite 

combustible materials. Heat may reach inflammable materials that are not visible or obvious. 

 

 

Protect the device from damp and wet! 

 
 

WARRANTY AND LIABILITY

 

 

Warranty and liability apply from the date of purchase (documented by the invoice/delivery note) according to 
the  currently  valid  general  terms  of  business  of 

BAK

 

GmbH. 

BAK

 

refuses  to  honour  any  warranty  for 

devices which are not in their original condition. BAK devices may never be reconfigured and/or modified.  

BAK

 

reserves the right to deny any responsibility if this is ignored. No liability can be assumed by 

BAK

 

for 

incorrect installation and/or use as well as natural wear and tear of components (e. g. heating elements). 

 

Note: 

This operating manual must be available to the installation and operating personnel at all times. Read these 
operating instructions carefully before installing and using the device. 

 

Copyright: 

This document must not be disclosed to third parties without the explicit written approval of 

BAK

 

GmbH. Any 

forms of reproduction or copying and electronic storage are prohibited. 
 

Formatiert

Summary of Contents for ROOFON

Page 1: ...OPERATING MANUAL BA RoofOn V30 R16 12_2012 GB mit CE BAK doc RoofOn RoofOn R Edge...

Page 2: ...rotection the device must be connected to a residual current circuit breaker before using it on construction sites Do not leave the device unobserved Hot air radiation of the hot air device may ignite...

Page 3: ...or when advised how to use the device by that person Children must be supervised in order to ensure that they do not play with the device Because of the enormous fire danger the operating personnel mu...

Page 4: ...ed risks to the life and health of the operating personnel when the machine is used in accordance with its intended use DANGER ZONE The main danger zone of the welding machine is the nozzle which can...

Page 5: ...rive starts automatically when the welding machine is swivelled in The welding speed is adjusted with the potentiometer or control unit depending on the plastic film geomembrane liner or weather condi...

Page 6: ...NCE AND SUPPORT The HERZ group and its authorised service centres offer free support and assistance in the area of applications technology Our specialists will be pleased to help you ACCESSORIES Avail...

Page 7: ...elivery by the carrier The seller must be promptly informed in writing Storage In the case of temporary storage the welding machine should be kept packed and must be protected from moisture In the cas...

Page 8: ...stment 50 100 4 Welding speed adjustment 0 6 12 5 m min 4 1 Welding speed adjustment 0 6 12 5 m min 4 1 1 Reduce speed 4 1 2 Increase speed 5 Heating ON OFF 6 Welding temperature adjustment 6 1 Weldin...

Page 9: ...Allen keys SW3 5 8 0 Assembly instructions for additional weight 8 1 Switch off the device unplug it and let it cool down if necessary 8 2 Screw out the M6x10 threaded bolt Allen SW3 8 3 Add additiona...

Page 10: ...uired tools Allen key SW6 9 0 Running wheel relocation edge roller assembly 9 1 Switch off device 9 2 Unplug device 9 3 Lay device on its side 9 4 Remove Allen screw of the guide handle SW6 9 5 Assemb...

Page 11: ...SPARE PARTS DRAWINGS Heating element and tube adapter Lifting device 5230043 5230044 5230045 5230169 5202010 6101760 5101270 5113269 5113267 5230054 5230112 5280284 5230036 5230055 5230037 5230097 51...

Page 12: ...054 Push rod tightener for lifting device 1 5230112 Fastening angle for lifting device 1 5280284 Rounded head screw M5x20 Torx 3 5230036 Centring push rod for lifting device 1 5230055 Guide roller 3 5...

Page 13: ...3 3 2008 EN61000 6 2 2005 EN61000 6 4 2007 A1 2011 EN60335 1 2012 _____________________________ Mag Marion Herz Degenkolb Gerente Sch nberg 30 01 2011 Portugu s Declara o de conformidade HERZ GmbH A...

Page 14: ...007 A1 2011 EN60335 1 2012 _____________________________ Mag Marion Herz Degenkolb ener ldirektors Sch nberg 30 01 2011 Dansk Conformiteitsverklaring HERZ GmbH A 6141 Sch nberg Austria bekr fter at de...

Page 15: ...ag Marion Herz Degenkolb Sch nberg 30 01 2011 Norsk Deklaration av samsvarsm ling fra HERZ GmbH A 6141 Sch nberg bekrefter at denne modellen av v rt solgte produkt oppfyller kravene i f lgende EF dire...

Page 16: ...16 BA RoofOn V30 R16 12_2012 GB mit CE BAK doc...

Reviews: