Figure 83: Drive Settings Screen
Table 22: Parameters
Parameter
Default
Description
Min Frequency
30Hz
Minimum frequency the drive is to
run. Set based on well conditions
to ensure adequate flow of well
fluids across motor to ensure
adequate cooling.
For ESP
applications, Min Frequency
settings below 30 Hz are not
recommended.
Max Frequency
60Hz
Maximum frequency the drive is
to run. The V/F curve will ensure
that the drive operates at the
DriveMaxVolts when running at
Max Frequency. This parameter
may NOT be changed while the
drive is running.
Accel Seconds
5 Seconds
Time in seconds for the drive
to ramp up from 0 Hz to
Max Frequency.
For ESP
applications, maximum
recommended Accel Seconds
is 10.0.