Copyright 2020 Baker Hughes Company. All rights reserved.
Page 185 of 277
Figure 161: Digital Output Screen
5. The digital output was specified as Normally Open so press the NO function button. The final trigger info
Figure 162: Final Trigger Info Screen, page 184
Figure 162: Final Trigger Info Screen
The output is shown and has been renamed to include the trigger name.
The digital output will remain open as long as the MtrTempHi Warn trigger is clear. If the motor temperature
exceeds 180 DegF, the trigger will transition to Set and digital output M3-M4 will close.