Table 2: Quick Start Parameters for Switchboard Applications (cont'd.)
Parameter Name
Default
Information
PwrFail SysStop Restart Delay
G60 Minutes
Restart delay after a power loss
when running. The default value
is the global restart time. When
the value is changed, the user
can specify whether the new
value applies only to the PwrFail
SysStop trigger or if the global
restart time should be changed.
ManualStartOnly
True
When set to true, the drive will
only start when the Start button
on the keypad is pressed. When
set to false, the drive will also
start on automatic restarts and
SCADA start commands. By
default, ManualStartOnly is set to
true any time a configuration or
a template is loaded to prevent
unexpected startup.
Setting ManualStartOnly to false enables automatic starts without warning and may cause
equipment damage, injury to personnel or death.
2 I Want To...
2.1
Set Pump Speed
Section 4.11 Adjust Setpoint, page 125
2.2
Change Color Scheme
From the Home Screen, repeatedly press the Settings function button until the Color Scheme setting
window appears. Use the Right and Left Arrow buttons to select the desired color scheme. Press the
Save function button and then confirm the change.
2.3
Log In/Access the Main Menu
You must be logged in to access the Menu. From the Home Screen, press the Settings function button
and then the Log In function button. By default, the level 2 password is 9 (just press the Down Arrow
button one time). After logging in, the Log In function button is replaced by Menu. Press the Menu function
button to access the main menu.