Copyright 2020 Baker Hughes Company. All rights reserved.
Page 218 of 277
Table 51: Apollo I/O Board (If Needed) (cont'd.)
From
To
ESP DSI J204-5 (GND)
Apollo I/O Board J108-5 (GND)
ESP Cable Shield
Apollo I/O Board J108-4 (SHIELD)
ESP DSI J204-3 (B)
Apollo I/O Board J108-3 (B)
ESP DSI J204-2 (A)
Apollo I/O Board J108-2 (A)
Table 52: ESP DSI
From
To
Apollo I/O Board J108-6 (+24 Vdc)
ESP DSI J204-6 (+24 Vdc)
Apollo I/O Board J108-5 (GND)
ESP DSI J204-5 (GND)
Apollo I/O Board J108-3 (B)
ESP DSI J204-3 (B)
Apollo I/O Board J108-2 (A)
ESP DSI J204-2 (A)
Downhole Sensor Choke Panel (Ve+)
ESP DSI J206-1 (VE+)
Downhole Sensor Choke Panel (Ve-)
ESP DSI J206-2 (VE-)
8.2.3
Configuration
Vector VII/Vector Plus applications use the Standard template that is automatically installed
with Apollo. Perform basic setup sequence as described in section 4. If an Apollo Extended
I/O board is included in the system, activate the board as described in
8.3
Vector VII/Vector Plus SPS Application
8.3.1
Equipment Needed
Table 53: Equipment
Part
Part Number
Apollo HMI (only if upgrading from
old
“Blue Box” HMI)
810283 (810286 if stainless steel)
Apollo I/O, ESP DSI Panel
(if adding full panel with I/O and ESP
DSI boards)
197207
Summary of Contents for Apollo 3
Page 1: ...Copyright 2020 Baker Hughes Company All rights reserved Page 1 of 277...
Page 266: ...Copyright 2020 Baker Hughes Company All rights reserved Page 266 of 277 Figure 227 USB Menu...
Page 267: ......
Page 276: ......