© 2021 Baker Hughes Company. All rights reserved.
28 | Baker Hughes
SIRA Approved Version
Installation must be in accordance with current applicable country codes and
manufacturer’s instructions.
Maximum pressure 100 psi.
Intrinsically Safe:
Installation must be in accordance with current editions of applicable
country codes, Figure 14 on page 32
, and manufacturer’s instructions.
Housing protection rating IP 66.
Do not open when energized. Do not open when an explosive gas
atmosphere is present. Use cables rated to ≥ 5°C above ambient.
For flameproof (Ex d protection concept):
The marking of the equipment shall include the following:
ITS19ATEX15058X
II 2GD
Ex db h IIC T6 Gb
T
a
= -40°C to +55°C
Ex db h IIC T5 Gb
T
a
= -40°C to +70°C
Ex db h IIC T4 Gb
T
a
= -40°C to +85°C
Ex tb IIIC T90° Db
T
a
= -40°C to +55°C
WARNING