© 2018 Baker Hughes, a GE company, LLC. All rights reserved.
36 |
=
BHGE
3. Set rod-ends and brackets to stroke and size of actuator. The default setting is a
4.00” stroke. Other stroke settings are as in Figure 19.
Figure 19
Stroke Settings
4. Mount take-off bracket to stem block at angle which keeps turnbuckle assembly
parallel to stem (Figure 20) using:
a. For top: two plain 5/16 flat washers, helical spring washer 5/16, two hex nuts 5/
16-18 regular.
b. For bottom: hex nut regular 1/4-20 and hex screw 1/4-20 UNC x 22.2 [.88] LG.
Figure 20
Bracket Configuration Strokes .5 - 2.50” and 3-6”
Summary of Contents for Masoneilan SVI II AP
Page 6: ...This page intentionally left blank...
Page 10: ...This page intentionally left blank...
Page 68: ...This page intentionally left blank...
Page 90: ...2018 Baker Hughes a GE company LLC All rights reserved 90 BHGE Spare Parts...
Page 92: ...2018 Baker Hughes a GE company LLC All rights reserved 92 BHGE...
Page 94: ...This page intentionally left blank...
Page 102: ...This page intentionally left blank...
Page 105: ...This page intentionally left blank...
Page 106: ...This page intentionally left blank...
Page 107: ...This page intentionally left blank...