Masoneilan SVI3 Installation and Maintenance Manual
=
| 29
© 2021 Baker Hughes Company. All rights reserved.
Figure 10 Camflex with Mounting Bracket (Side View)
6. Align the end of the magnet holder flush with the end of the mounting bracket (Red
Dotted line in the Figure 10 on page 29). Secure the magnet holder with two M6 set
screws using 6mm Hex Key.
7. Slide the V-Seal over the magnet holder.
8. Secure the SVI3 onto the mounting bracket with four M6 x 20 mm socket head cap
screws using 6mm Hex Key.
9. Ensure that:
• No interference exists with the position sensor protrusion.
• Ensure that the V-Seal makes contact with the skirt around the position sensor
protrusion on SVI3 housing.
3.4.2.1 Checking the Magnet
There are two methods of checking the SVI3 magnet:
• Perform a visual inspection
• Use SVI3 DTM with Valvue3 to check the magnet
3.4.2.2 Performing a Visual Inspection
Ensure that the magnet is aligned as in Table 2 on page 28.
Shaft Extension
Lock Magnet
Assembly
Flush w/Top
of Bracket
V-Seal
Magnet
Holder