background image

bakerhughes.com

Copyright 2021 Baker Hughes Company. All rights reserved. Baker Hughes provides this 
information on an “as is” basis for general information purposes. Baker Hughes does not 
make any representation as to the accuracy or completeness of the information and makes 
no warranties of any kind, specific, implied or oral, to the fullest extent permissible by 
law, including those of merchantability and fitness for a particular purpose or use. Baker 
Hughes hereby disclaims any and all liability for any direct, indirect, consequential or special 
damages, claims for lost profits, or third party claims arising from the use of the information, 
whether a claim is asserted in contract, tort, or otherwise. Baker Hughes reserves the right 
to make changes in specifications and features shown herein, or discontinue the product 
described at any time without notice or obligation. Contact your Baker Hughes representative 
for the most current information. The Baker Hughes logo, Masoneilan, SVI and Camflex are 
trademarks of Baker Hughes Company. Other company names and product names used in 
this document are the registered trademarks or trademarks of their respective owners.

BHMN-SVI3-QSG-34605A-0321 

03/2021

Tech Field Support & Warranty:

Phone: +1-866-827-5378

valvesupport@bakerhughes.com

Find the nearest local Channel Partner in your area:

valves.bakerhughes.com/contact-us

valves.bakerhughes.com

Direct Sales Office Locations

Australia

Brisbane

Phone:   +61-7-3001-4319
Perth

Phone:   +61-8-6595-7018
Melbourne

Phone:   +61-3-8807-6002

Brazil

Phone:  +55-19-2104-6900

China

Phone:  +86-10-5738-8888

France

Courbevoie

Phone:  +33-1-4904-9000

India

Mumbai

Phone:  +91-22-8354790

New Delhi

Phone:  +91-11-2-6164175

Italy

Phone:  +39-081-7892-111

Japan

Tokyo 

Phone:  +81-03-6871-9008

Korea

Phone:  +82-2-2274-0748

Malaysia

Phone:  +60-3-2161-03228

Mexico

Phone:   +52-55-3640-5060

Russia

Veliky Novgorod

Phone:  +7-8162-55-7898
Moscow

Phone:  +7-495-585-1276

Saudi Arabia

Phone:  +966-3-341-0278

Singapore

Phone:  +65-6861-6100

South Africa

Phone:  +27-11-452-1550

South & Central 

America and the Caribbean

Phone:   +55-12-2134-1201

Spain

Phone:  +34-935-877-605  

United Arab Emirates

Phone:  +971-4-8991-777

United Kingdom

Phone: +44-7919-382-156

United States

Houston, Texas

Phone:  +1-713-966-3600

Summary of Contents for Masoneilan SVI3

Page 1: ...Masoneilan SVI 3 Digital Positioner Quick Start Guide Rev A Baker Hughes Data Classification Public...

Page 2: ...REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN...

Page 3: ...ng Procedure of SVI3 on Rotary Control Valves 6 8 Mounting Procedure of SVI3 on Reciprocating Control Valves 9 11 Tubing and Air Supply to SVI3 12 SVI3 Wiring Procedure 13 14 Local Commissioning with...

Page 4: ...can lead to injury or death Total compliance with all DANGER WARNING and CAUTION notices is required for safe operation This is the safety alert symbol It alerts you to potential personal injury haza...

Page 5: ...ivers accurate responsive and reliable positioning performance Note Refer to https valves bakerhughes com resource center for the following Free trial of ValVue3 and SVI3 DTM software mentioned in Sec...

Page 6: ...Camflex Tools required 3 16 Hex Key 5 32 Hex Key 3mm 4mm 5mm Hex Key 1 Attach the SVI3 rotary mounting bracket to the valve actuator with two 5 16 18 UNC flat head cap screws and tighten using 3 16 H...

Page 7: ...a wrench as shown across the top surface of the bracket Adjust height as necessary to make sure the magnet assembly is flush with the top of the mounting bracket Wrench tight the two M6 screws on the...

Page 8: ...20 mm socket head cap screws using 6mm Hex Key 4 Ensure that the V Seal makes contact with the skirt around the alignment ring on the SVI3 SVI3 Mounting Bracket Rotary Actuator Figure 5 Camflex with...

Page 9: ...m 5mm 6mm Hex Key 1 Mount the standard reciprocating mounting bracket to the valve with two 5 16 18 UNC cap screws and apply wrench tight Mounting hole selection for the bracket is defined in Table 2...

Page 10: ...uator Size Stroke Mounting Hole Lever Hole Turnbuckle Length 6 and 10 0 5 0 8 12 7 20 32 mm A A 1 25 31 75 mm 10 0 8 1 5 30 32 38 1 mm B B 16 0 5 0 8 12 7 20 32 mm B A 2 90 73 66 mm 16 0 8 1 5 20 32 3...

Page 11: ...read the turnbuckle onto the left hand threaded rod end approximately two turns Attach the left hand threaded rod end to the take off rod with 1 4 20 UNC nut and thread the left hand lock nut onto the...

Page 12: ...the tubing and all the fittings are leak free 3 Confirm that the air regulator is adjusted to the lowest setting prior to turning on air supply 4 Turn on the air supply and adjust the air regulator to...

Page 13: ...le cable gland as per the end user country regulations Lock Screw End Cover 1 2 NPT Housing Entries Figure 15 SVI3 Digital Positioner front view SVI3 Wiring Procedure The SVI3 uses a 4 20mA signal wit...

Page 14: ...tion of I O Two solid state switches SW 1 and SW 2 4 20 mA output to support position retransmit functions Digital Input DI Remote position sensor input Process Variable PV Figure 17 Optional Modual C...

Page 15: ...shown in the digital display Press and hold this button continuously the displayed value decreases at faster rate Launch the Smart Cal routine by following the process detailed below This button is i...

Page 16: ...pany All rights reserved The SVI3 pushbutton menu structure helps to perform device operations such as configuration calibration viewing data and viewing errors Note Refer SVI3 IOM for full button men...

Page 17: ...or the software installation HART Modem and device configuration procedures 1 Upon successful device connection and DTM launch the Online Parameters are displayed in the DTM screen 2 For device config...

Page 18: ...al for more details Click Setup Wizard on the left pane In the Setup Wizard screen choose the appropriate Air Action and the calibration will be performed automatically Put the device back to Normal m...

Page 19: ...VI3 DD files to the handheld communicator 2 Connect the handheld communicator as shown in Figure 14 and turn the power ON the home screen will be displayed as below 3 Select Online menu in the home sc...

Page 20: ...erations such as Change Device Mode Run Find Stops and Auto Tune 5 For device configuration or to run Find Stops and Auto Tune the device should be in the Setup mode Click Setup in the Set Mode Target...

Page 21: ...21 Baker Hughes Company All rights reserved Masoneilan SVI3 Quick Start Guide 21 6 Perform Find Stops and Auto Tune using the following screens for the device setup Figure 28 Run Find Stops and Auto T...

Page 22: ...22 Baker Hughes 2021 Baker Hughes Company All rights reserved Notes...

Page 23: ...2021 Baker Hughes Company All rights reserved Masoneilan SVI3 Quick Start Guide 23 Notes...

Page 24: ...s of Baker Hughes Company Other company names and product names used in this document are the registered trademarks or trademarks of their respective owners BHMN SVI3 QSG 34605A 0321 03 2021 Tech Fiel...

Reviews: