Bugbox Plus
UM-17 R4.0
Page 6 of 47
Bugbox Plus User Manual
Overview
Please read this manual carefully to familiarise yourself with the operation and maintenance of your
Bugbox Plus workstation. Note: The workstation should be located in a well-ventilated area.
Safety Instructions
For your safety, the safety of others using the workstation and those around you;
The covers on both ends and the top of the workstation must not be removed by anyone
other than a qualified service engineer. There are no end user serviceable parts within these
covers.
The AC Mains outlet that the workstation is connected to, MUST not be obstructed by the
workstation or any other equipment, and MUST be accessible in case of emergency. In case
of emergency, disconnect the workstation from the AC Mains Outlet.
In case of damage to the workstation disconnect the workstation from the AC Mains outlet
and contact your Local Distributor for advice
The workstation and stand must be connected to a protective earth.
Only the power cord supplied with the workstation should be used to connect the
workstation to the mains supply.
If an uninterrupted power supply is used, the Bugbox Plus must be connected to the
uninterrupted power supply.
Only Ruskinn Technology Limited replacement parts should be used.
Gas regulators must be used for each gas supply. A 2 stage regulator should be used for a
bottled gas supply. The maximum supply pressure permissible is 4 bar gauge.
The maximum permissible concentration of Hydrogen in the anaerobic mixed gas is 5.5%
Hydrogen.
The mains supply voltage fluctuations must not exceed +/- 10% of the nominal mains
voltage.
Only the gasses specified in this manual may be used.
The maximum power rating of the internal socket must not be exceeded.
The humidifier screw cap must not be covered or blocked.
The humidifier/ pressure relief tank must not be overfilled.
The spot light should not be used continuously for more than 10 minutes. The spot light
should be allowed to cool for at least 10 minutes between uses.
The cooling fan covers and cooling vents must not be covered or blocked.
The workstation should not be lifted by the glove ports, the interlock or the Single Plate
Entry System.
The weight limit for the rear shelf is 5.5kg. The weight must be evenly distributed.
The use of Radioactive materials in the workstation is strictly prohibited.
FAILURE TO ADHERE TO THESE SAFETY INSTRUCTIONS COULD CAUSE SERIOUS INJURY AND WILL
INVALIDATE THE WORKSTATION WARRANTY. RUSKINN TECHNOLOGY LIMITED ACCEPTS NO
RESPONSIBILITY FOR ANY ACCIDENT, INJURY OR LOSS CAUSED BY UNSAFE OPERATION OF THE
WORKSTATION