background image

4

Thermostats do not have to be turned off to turn off your griddle. The ON/OFF toggle switch allows the thermostats to
remain set at your cooking temperature when the griddle is OFF. When the main switch is ON the griddle automatically
heats to your pre-set cooking temperature.
Red indicator lights next to the thermostats are ON when the burners are in operation. When the set temperature is
reached, the light will goOFF.

All griddles are equipped with adjustable legs to provide a means for proper leveling during installation. The griddle can
be leveled by turning the bottom of the legs until the desired position is achieved. After leveling, the manifold should
then be connected to the gas line.

E. LEVELINGADJUSTMENT

2. LIGHTING INSTRUCTIONS

A. LIGHTING INSTRUCTIONS

1.

Turn off all thermostats or gas controls and main Shut-off valve and wait 5 minutes.

2.

Turn the main gas valve to ON position and light standing pilots through the holes in the front panel. (FIG.
B)

3.

Repeat the above step for all standing pilots. There should be slight yellow tip on the pilot flame. Make sure all
the pilots are lit.

4.

Turn the toggle switch on the front panel toONposition(XSGmodelonly)

5.

Set all thermostats to desired temperature.

7.

To relight follow steps 1-5.

The pilot assembly is located about 10” into the unit from the front panel. Use a BBQ match or a lighter

at least 10” long. Alternatively pilots are also accessible from the bottom of the unit and the distance is
approximately 6”. Insert a match or a lighter from the bottom of the unit while watching through the lighting
hole in the front panel to make sure all pilots light correctly.

Pilot should be approximately ½”- ¾” in height. Adjust as required by turning the pilot

adjusting screw located on themanifold pipe.

All burners must light and burn evenly. Flames are to be blue with

little or no traces of white or yellow. If they exhibit excessivewhiteoryellow flames, adjust the burner shutters.
Re-light burners and re-check. Repeat as required.

6.

The red indicator light on XSGmodel will indicate that themainburner is in operation.

A separate gas shut off valve (supplied with unit) must be installed in the gas line ahead of the unit, as required by
codes (see Fig.A)..Gassupplylinemustbe¾”orlarger.Ifflexiblesemirigidconnectionsareused, the inside diameter
must be the equivalent of ¾” iron pipe or larger. All connections of the flexible and semi rigid type must be AGA listed
and comply with applicable ANSI standards. Make sure gas piping is clean and free of dirt, piping compound and
obstruction. To insuremaximum operating efficiency, this appliance must be connectedwith a Gas Supply Line of solid
pipe or with a Commercial Type Flexible Connector with I.D. (inside diameter) equal or larger than the gas pipe inlet on
this appliance.

If the gas connections are leak-free, the unit is ready to use. Follow the lighting instructions.

The installation of electric wiring from the electric meter, the main control box, and the outlet to the electric appliance
must be electrically grounded in accordance with local codes, or in the absence of local codes with the National
Electric Code ANSI/NFPA 70. In Canada, follow the Canadian Electric Code CSA-C 22.2. All work should be done by
qualified installation personnel.

Electrical diagram (model XSG only) is located on the right side of the unit.

CAUTION: BEFORE LIGHTING, CHECKALLJOINTS IN THE GAS SUPPLY LINE FOR LEAKS. USE SOAPAND
WATER SOLUTION. DO NOTUSEOPENFLAME.

D. ELECTRIC INSTALLATION (XSG ONLY)

This appliance when installed must be electrically grounded in accordance with local codes, or in the
absence of local codes, with the

or the

as applicable.

WARNING-ELECTRICALGROUNDING INSTRUCTION

This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and
should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the
grounding prong from this plug.

National Electrical Code, ANSI/NFPA 70,

Canadian Electrical Code,

CSAC22.2,

Summary of Contents for CookLine XMG-24

Page 1: ...vice when used according to the instructions in this manual and standard commercial kitchen practices Instructions must be posted in a prominent location All safety precautions must be taken in the ev...

Page 2: ...120 000 XSG XTG XMG 60 150 000 150 000 XSG XTG XMG 72 180 000 180 000 GAS SPECIFICATIONS Propane Gas Natural Gas BTU HR 10 W C BTU HR 3 5 W C Model Number XSG This appliance will not operate during a...

Page 3: ...GasCodeANSI Z223 1 latest edition In Canada it must conform to current National Standard CAN CGA B 149 1 natural gas or CAN CGAB149 2 propane Installation Code for Gas BurningAppliances Equipment 7 El...

Page 4: ...ewhiteoryellow flames adjust the burner shutters Re light burners and re check Repeat asrequired 6 The red indicatorlight on XSGmodel will indicate that themainburner is in operation A separate gas sh...

Page 5: ...OFFGASSUPPLYandremovefrontpanel Disconnect the powersupply before cleaning or servicing A MAINTENANCE To provide proper operation and insure the safety of the user this equipment must be maintained an...

Page 6: ...576 0605 1 800 431 2745 www bakerspride com fax US Canada web address Gas Counter Top Griddles XMG XTG XSG 24 36 48 60 72 11 11 12 13 13 14 15 16 17 18 19 21 22 23 24 25 26 27 28 1 2 3 4 5 6 7 7 8 8...

Page 7: ...LOT DOUBLE 1 8X27 x 3 16 VALVE PILOT SINGLE 1 8X27 x 3 16 PRESSURE TAP NOZZLE NOT SHOWN VALVE GAS SHUT OFF INDICATOR LIGHT RED SOLENOID VALVE DUAL GAS SOLENOID VALVE SINGLE GAS POWER CORD BRASS FITTIN...

Page 8: ...the product The serial number rating plateaffixed to the equipment has not beendefaced or removed WHO IS COVERED This warranty is extended to the original purchaser and applies only to equipment purch...

Reviews: