E. ELECTRICAL CONNECTION:
Install according to the spacing requirements listed in the installation section of this manual. We strongly
recommend having a competent professional install this equipment. A licensed electrician should make
the electrical connections and connect power to the unit. Local codes should always be used when
connecting these units to electrical power. In the absence of local codes, use the latest version of the
National Electrical Code.
Note: For supply connections use No. 6AWG wires suitable for at least 90°C.
SUITABLE FOR INSTALLATION ON COMBUSTIBLE FLOOR WHEN
INSTALLED WITH LEGS OR CASTERS PROVIDED.
!
!
CAUTION: DO NOT SET THE OVEN WITH ITS BACK FLAT AGAINST THE
WALL. IT WILL NOT OPERATE PROPERLY UNLESS THERE IS AT LEAST
THREE INCHES BREATHING SPACE BEHIND THE OVEN
!
!
NOTICE: LOCAL CODES REGARDING INSTALLATION VARY GREATLY
FROM ONE AREA TO ANOTHER. THE NATIONAL FIRE PROTECTION
ASSOCIATION, INC., STATES IN IT’S NFPA96 LATEST EDITION THAT LOCAL
CODES ARE “AUTHORITY HAVING JURISDICTION” WHEN IT COMES TO
REQUIREMENTS FOR INSTALLATION OF EQUIPMENT. THEREFORE,
INSTALLATIONS SHOULD COMPLY WITHALLLOCALCODES.
!
!
C. INSTALLATION WITH CASTERS (OPTIONAL):
UL 197: Electrical Supply Connections For Permanently Connected Appliances.
Oven Restraint:
D. LOCATIONAND MINIMUM CLEARANCES:
Four casters (two with wheel brakes) and the mounting hardware are packed and included in the
shipment if ordered. Install casters with wheel brakes on the front of the unit. Installation must conform
to
It requires that
permanently connected appliances with casters be provided with a means for securing the appliance to
the building structure to limit the movement of the appliance.
When casters are installed on either a single or double unit, a fixed restraint must be
used to limit the movement of the appliance without depending on or transmitting stress to the electrical
conduit. The restraint (a heavy-gauge cable) should be attached to the rear legs of the oven on which
casters are mounted. If disconnection of the restraint is necessary, the restraint must be reconnected
after the oven has been repositioned in its permanent location. The appliance shall be installed using
flexible conduit.
Move the oven to its final location keeping the minimum clearance from the back of the oven to the wall.
This clearance is necessary for safe operation and to provide proper air flow.
RIGHT WALL
1”
LEFT WALL
1”
REAR WALL
3”
Under Ventilation Hood
MINIMUM CLEARANCES FROM COMBUSTIBLEAND NONCOMBUSTIBLE CONSTRUCTION