LIGHTING INSTRUCTIONS:
Regulator pressure must be measured and adjusted before the unit goes into service, following installation
and when operational performance is in question. A soft blue flame, just short of a yellow tip, gives the best
results; combustion air can be adjusted by opening or closing the air shutter slightly.
Radiant Series C, F, L Models without safety pilot
A. Turn all burners to OFF.
B. Remove the top grid(s).
C. Remove the last radiant(s) closest to
GAS SETTINGS
Regulator pressure must be measured and adjusted before the unit goes into service, following installation
and when operational performance is in question. A soft blue flame, just short of a yellow tip, gives the best
results; combustion air can be adjusted by opening or closing the air shutter slightly.
D. Turn the runner tube valve to ON.
E. Light the runner tube.
(Note: If the runner tube does not light, wait a the side(s) of the unit. few seconds,
then try again.)
F. Replace the radiant(s) and top grid(s). Push and turn the burner valves to operate the individual burners
as needed.
G. If any burner fails to light from the runner tube, shut off all the burners and the runner tube. Do not attempt
to re-light for five minutes after shutdown. Repeat steps a thru f. If unit still fails to operate properly,
contact authorized service personnel.
Broiler Shut Down
Turn all burners to OFF.
Turn the runner tube valve to OFF.