background image

BUILT BY CRAFTSMEN. TESTED BY TIME

®

.

SERIES: GP

OPERATION MANUAL

HEARTHBAKE SERIES COUNTERTOP GAS OVENS

Summary of Contents for GP-52 Double

Page 1: ...BUILT BY CRAFTSMEN TESTED BY TIME SERIES GP OPERATION MANUAL HEARTHBAKE SERIES COUNTERTOP GAS OVENS ...

Page 2: ...inent location in the kitchen area This information shall be obtained from the local gas supplier NOTICE BAKERS PRIDE OVEN COMPANY LLC 1307 N Watters Rd Suite 180 Allen TX 75013 Phone 800 527 2100 Fax 914 576 0605 www bakerspride com P N U4128A 9 18 IMPORTANT INSTRUCTIONS After the gas supply has been connected to your unit it is extremely important to check piping for possible leaks To do this us...

Page 3: ...nt 8 Oven Interior 8 Baking Chamber 8 Baking Decks 9 Burner Compartment 9 Troubleshooting Chart 9 EXPLODED VIEWS PARTS LISTS GP 51 Parts List w Exploded Views 10 GP 61 Parts List w Exploded Views 13 WARRANTY 16 For European Communities EN 437 Gas Cat Gas and Supply Pressures Designated European Market u A T B E D K F I F R G R D E I E I T L U N L P T E S S E G B I2H G20 20mbar u u u u u u u u u I2...

Page 4: ...ion Minimum Clearance from Left Side 2 51mm 2 51mm Minimum Clearance from Right Side 1 25mm 0 Minimum Clearance from Rear 5 127mm 2 51mm Set Up Your oven is packed in a carton and strapped to a skid Remove the oven and carton from the skid before unpacking Unpack carefully to avoid damage to the oven If concealed damage is found follow the instructions detailed in Section 1 Keep the area around th...

Page 5: ... the Standard for Connectors for Movable Gas Appliances ANSI Z21 69 in the USA CAN CGA 6 16 in Canada and a quick disconnect device that complies with the latest edition of the Standard for Quick Disconnect Devices for use with gas fuel ANSI Z21 41 in the USA CAN CGA1 6 9 in Canada and adequate means must be provided to limit the movement of the appliance without depending on the connector and any...

Page 6: ...ction in compliance with EN 60335 1 and or local codes c The ovens should not be installed on the same line with space heaters boilers or other gas equipment with high intermittent demand d Use a pipe joint compound that is resistant to the action of liquefied petroleum gases when making gas connections e For Propane gas use at least 1 2 13 mm pipe or tubing with a 5 8 16 mm inside diameter For Na...

Page 7: ...ect Venting Optional Not Available For European Community Countries If direct venting it is necessary to install a draft hood fig 2 The flue pipe from the draft hood must not run downwards at any point from the oven to the final outlet It should always slant slightly upwards For best results it should rise straight up Do not put a damper in the flue and do not connect a blower directly to the flue...

Page 8: ...e That indicates a good mixture of gas and air When using LP gas the flame will have a blue yellow appearance Should the Burner fail to light check to see if there is a problem with the gas supply If there are other appliances on the same line shut them off temporarily and see if the burner comes back on or it fluctuates as other gas appliances are turned on and off That would indicate overloading...

Page 9: ...a pan When you determine the combination of method ingredients and temperature that gives the right bake for your crust sauce and cheese combination and your customer s taste mark and keep it Deck baking refers to baking Pizza directly on the deck Generally it is a thin product that requires temperature of at least 550 F 290 C Screen baking refers to baking Pizza on a screen The screen lifts the P...

Page 10: ...gent solutions and cleaners that meet the national and or local codes Baking Chamber Clean the ceiling and the walls of the baking chamber with a mild soap and water solution Do not use oven cleaners caustic solutions or mechanical means as they will damage the interior aluminized surface e Bubbles in fresh dough indicate under proofed or cold product Allow the dough balls to proof to double in si...

Page 11: ...not light Gas valve feeding oven may be in the closed position Turn gas valve on Relight pilot Thermopile may not be positioned in pilot flame Ensure that the tip of thermopile is in pilot flame Thermopile may be defective Call local authorized Bakers Pride Service Agent Oven too Hot Thermostat set too high Lower the thermostat setting and see if flame reduces in size Allow several hours for heat ...

Page 12: ...COUNTERTOP GAS DECK OVEN OPERATION MANUAL 10 EXPLODED VIEWS PARTS LISTS Figure A GP 51 Exterior Deck Burner Compartment Rod Door Interior Trim ...

Page 13: ...CASTERS W LOCKS Burner Compartment ITEM PART DESCRIPTION 35 A5258X UPPER BREATHER PAN 36 A5321K FLUE DEFLECTOR SET LEFT RIGHT 37 A5237X SLIDE OUT FLAME DIVERTER 38 A5341K INSULATION PAN SET TOP BOTTOM 39 A5301K COMBUSTION CHAMBER FRONT CENTER 40 A5302K BURNER ACCESS COVER 41 S3203X MAGNETIC LATCH ASSEMBLY Door Rod Accessories Intertior Trim ITEM PART DESCRIPTION 42 A5288X SPRING BRACKET 43 A5291X ...

Page 14: ...BLANK SPUD 2 FOR 2 INSPIRATOR 69 M1296X THERMOCOUPLE T 46 USED W BGOR Figure B GP 51 Burner Figure C GP 51 Plumbing Control ITEM PART DESCRIPTION 70 M1392X CONTROL ASSY TO UNION N G BGOR 71 M1393X CONTROL ASSY TO UNION L P BGOR 72 M1005X THERMOSTAT 73 S1056X THERMOSTAT KNOB F 74 S1163X THERMOSTAT KNOB C 75 R3152X 7000 COMBO VALVE N G BGOR 76 R3154X 7000 COMBO VALVE L P BGOR 77 M1297X N G BGOR VALV...

Page 15: ...COUNTERTOP GAS DECK OVEN OPERATION MANUAL 13 EXPLODED VIEWS PARTS LISTS Figure A2 GP 61 Exterior Deck Burner Compartment Rod Door Interior Trim ...

Page 16: ...IVERTER 38 A5259X INSULATION PAN SET TOP BOTTOM 39 A5251X COMBUSTION CHAMBER FRONT CENTER O S 40 A5252X BURNER ACCESS COVER O S 41 A5301K COMBUSTION CHAMBER FRONT CENTER 42 A5302K BURNER ACCESS COVER 43 S3203X MAGNETIC LATCH ASSEMBLY Door Rod Accessories Intertior Trim ITEM PART DESCRIPTION 44 A5288X SPRING BRACKET 45 A5291X LEFT DOOR STOP 46 A5292X RIGHT DOOR STOP 47 A5293X DOOR STOP SHIELD FITS ...

Page 17: ... GP 61 Burner Figure C2 GP 61 Plumbing Control ITEM PART DESCRIPTION 76 M1392X CONTROL ASSY TO UNION N G BGOR 77 M1393X CONTROL ASSY TO UNION L P BGOR 78 M1290X CONTROL ASSY TO UNION N G BMVR O S 79 M1291X CONTROL ASSY TO UNION L P BMVR O S 80 M1005X THERMOSTAT 81 S1056X THERMOSTAT KNOB F 82 S1163X THERMOSTAT KNOB C 83 R3152X 7000 VALVE BGOR N G AFTER SN339 8 98 84 R3154X 7000 VALVE BGOR L P AFTER...

Page 18: ...adiants Stones and Valves are covered for a period of SIX MONTHS All Ceramic Baking Decks are covered for a period of THREE MONTHS The installation of these replacement decks is the responsibility of the purchaser The extended Cyclone door warranty years 3 through 5 is a parts only warranty and does not include labor travel mileage or any other charges EXCLUSIONS Negligence or acts of God Failures...

Page 19: ...TANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment For Warranty Service and or Parts this information is required Model Number Serial Number Date Purchased ...

Page 20: ...18 NOTES ...

Page 21: ...19 NOTES ...

Page 22: ...t offering a wealth of refrigeration and cooking expertise Products include walk in coolers and freezers hot and cold display cabinets cases and storage systems commercial ovens rotisseries and cooking equipment and rotary vane pumps Ask your sales representative about how the power of all Standex brands can work for you www standex com segments food service Food Service Equipment Group ...