5

2. LIGHTING INSTRUCTIONS

A

If you have any questions concerning the installation, operation, maintenance or service of

this product please contact

Technical Service Department at (800) 431-2745 US & Canada

1. Turn off all gas valves and main Shut-off valve and wait 5 minutes.

2. Turn the main gas valve to ON position and light standing pilots adjacent to each main burner. (FIG. A & B)

3. Repeat the above step for all standing pilots. There should be slight yellow tip on the pilot flame. Make sure all

the pilots are lit.

4. Turn the main burner valve to the ON position.

5. To relight follow steps 1-4.

For completeshut down turn all the main burner valves and main gas valve to OFF position.

Clean the unit regularly after use. Burner ports and burner rest should be thoroughly cleaned. Top grates are

easily removable.After cleaning rinse with clean water and dry with a dry cloth.

Heavy sputteringor spills may require cleaning with a mild oven cleaner.

Use mild soap or detergentto clean chassis and stainless steel parts.

To service burners or pilots TURN OFF GAS SUPPLY and remove top grates.

B. SHUTDOWNINSTRUCTIONS

3. MAINTENANCEINSTRUCTIONS

A. CLEANINGINSTRUCTIONS

·

·

·

·

To provide proper operation and insure the safety of the user, this equipment must be maintained and serviced by a trained

maintenance person or an authorized service agency at regular intervals.

1.

Burner ports must be thoroughly cleaned. Venturi must be free from grease and lint.

2.

All places where oil, grease or food can accumulate must be kept clean all the time.

3.

Pilot light must be kept clean and adjusted at the proper flame height to assure constant ignition and to prevent fire flash-

outs caused by delayed ignition.

4.

Carelessness, abusive handling, or altering equipment can shorten the life of the equipment and jeopardize the limited

warranty offered by Baker's Pride.

Pilot should be approximately½”- ¾” in height. Adjust as required by turning the pilot adjusting

screw located on the manifoldpipe.

B. MAINTENANCEINSTRUCTIONS

Figure “B”

GAS VALVE

All manuals and user guides at all-guides.com

Summary of Contents for XOB-424

Page 1: ...Y Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or Maintenance can cause...

Page 2: ...ease complete this information and retain this manual for the life of the equipment For Warranty Service and or Parts this information is required Model Number Serial Number Date Purchased All manuals...

Page 3: ...nnection 4 Leveling Adjustment 4 Lighting Instructions 4 Shutdown Instructions 5 Cleaning Instructions 5 Maintenance Instructions 5 Parts List Exploded View 6 A B C D A B A B C 11 GAS SPECIFICATIONS P...

Page 4: ...rrent natural gas or 7 The appliance and its individualshut off valve must be disconnectedfrom the gas supply piping system duringanypressuretestingofthatsystemattestpressuresinexcessof psi 3 45kPa 8...

Page 5: ...mildsoapordetergenttocleanchassisandstainlesssteelparts ToserviceburnersorpilotsTURNOFFGASSUPPLYandremovetopgrates B SHUTDOWN INSTRUCTIONS 3 MAINTENANCE INSTRUCTIONS A CLEANING INSTRUCTIONS To provide...

Page 6: ...A R1151A R1150A Front Venturi Rear Venturi Gas Valve Knob Aluminum Tubing 3 16 Pilot Burner Rating Plate Orifice Nat 38 Orifice LP 52 Burner Cast Iron Grate 12 x 13 Cast Iron Leg 6 Manifold 48 Manifol...

Page 7: ...7 Notes All manuals and user guides at all guides com...

Page 8: ...serialnumberratingplateaffixedtotheequipmenthasnotbeendefacedorremoved WHO IS COVERED This warranty is extended to the original purchaser and applies only to equipment purchased for use in the U S A C...