background image

Centrer le four dans le meuble et le fixer à l'aide des 

vis (4x25) fournies.

Si le meuble a été construit en respectant les dimensions 

fournies, une fente d'aération doit subsister au niveau de la 

partie supérieure du four. Ne pas boucher cette fente 

d'aération avec des baguettes en bois, afin de permettre une 

bonne ventilation.

Une distance d'au moins 5 mm doit être respectée entre 

l'appareil et les meubles voisins (meubles situés à côté du 

four).

Démontage

Débrancher le four du secteur électrique. Desserrer les vis de 

fixation du four au meuble. Soulever légèrement le four et 

l'extraire entièrement du meuble.

en

Ú

 Ins tallation ins tructions

Preparing the unit: figure 1

For the housing units, the sheets and plastic coatings must 

have been completed using an adhesive which is heat-

resistant at 90 ºC for the unit interior (where the oven will be 

positioned) and 70 ºC for the adjacent units (located to the 

side of the oven). If the sheets and plastic coatings or the 

adhesive do not have sufficient heat resistance, the units may 

become deformed or burned. In this case, the oven 

manufacturer cannot be held responsible for the damage 

caused to the unit.

The units must be cut before installing the oven. Remove any 

wood chippings as they could affect the working of the oven 

components.

The oven connection box must be positioned in shaded 

surface area

B

 or in an area where it does not interfere with 

the oven assembly.

Any free-standing units must be fastened to the wall at the 

normal angle

C

.

The oven housing unit requires a ventilation opening at the 

base.

If the oven is fitted below a hob, follow the hob's assembly 

instructions.

Fitting the oven in a high unit: figure 2

The oven can also be assembled in a high unit. 
For ventilation, there should be a 20 mm gap approximately 

between the lower shelf and supporting wall and another 

20 mm gap between the upper shelf and supporting wall.
It is recommended that a gap of 590 mm is left between the 

lower and upper shelf for proper ventilation. This gap could be 

increased to 595 mm if you want greater ventilation than 

recommended.
Ovens with a pull-out carriage door should be assembled so 

that the baking trays can be easily removed.

Assembling the oven in a corner: figure 3

When assembling the appliance in a corner, the dimensions in 

figure

D

 must be taken into account. It is recommended that for 

the measurements in figure

E

, the width of the front part of the 

unit and the handle are taken into account.

Connecting the oven to the mains

Before using the appliance for the first time, you must check 

that your house has an earth connection and fulfils all the 

applicable safety standards. Your appliance must be installed 

by an authorised technician. The requirements of the regional 

power supply company and national ones apply.
The use of this appliance without an earth connection or when 

not installed correctly can cause serious damage (personal 

injury and death by electrocution), albeit this is highly unlikely. 

The manufacturer accepts no responsibility for any malfunction 

or damage which is caused by unsuitable electrical 

installations.

The oven must be disconnected from the mains during all 

assembly operations.

The oven has class I protection and should only be operated 

with an earth connection.

The cable for connecting the oven to the mains must be 

H05 V V-F 3G 1.5 mm² or higher.
The yellow and green colour cable, which is used for the earth 

connection, should be connected first and should be longer 

than the others.

To fulfil the normal safety requirements, the installation 

technician should ensure that a cut-off switch is installed on all 

poles with a contact opening of less than 3 mm. This is not 

necessary if the appliance is connected via a plug, if this is 

accessible to the user, and provided it is earthed.

The assembly must ensure protection against manual contact.

The oven must be connected taking into account the voltage 

indicated on the oven's specifications plate.

To connect the appliance it should be positioned in front of 

the unit. The connection cable should be long enough to 

ensure connection.
Warning! Make sure the connection cable does not become 

trapped during installation and that it does not come into 

contact with the hot parts of the oven.

Any handling of the appliance, including changing or installing 

the power cable, must be performed by the Technical 

Assistance Service.

Positioning the oven in the unit: figure 4

For ovens with a pull-out carriage door, the door must be 

removed.

Push the oven completely into the space in the unit provided 

for this purpose. Make sure the cable has not been stripped 

by the oven edges, that it is not in contact with hot parts and 

that it does not run along the bottom of the oven.

Centre the oven in the unit and fasten with the screws (4x25) 

supplied.

If the unit has been built according to the measurements 

provided, there will be a gap at the top of the oven. Do not 

cover this gap with wooden slats so as to allow sufficient 

ventilation.

There should be at least a 5 mm gap between the appliance 

and the adjacent units (located beside the oven).

Dismantling

Disconnect the oven from the mains. Loosen the screws that 

fasten the oven to the unit. Lift the oven slightly and remove it 

completely from the unit.