27
CIRCUIT BREAKER INSTALLATION
The circuit breaker sub-panel has space for up to 8 single
position or 4 double position circuit breakers. The installer
is responsible for providing circuit breakers of appropriate
ratings. See the table below for a list of the approved
breakers that can be used. This information is also located on
a label inside the enclosure door.
CONTROL ELECTRONICS POWER CONNECTION
The System Control Center requires 120VAC power to operate
the control electronics and the chlorine generator. Wire the
2-position terminal block to an installer supplied 120VAC
breaker with a 20A maximum rating. See below.
The two 10 AMP dimmable 120VAC light circuits are also
powered through this connection. The neutral connection is
factory pre-wired from the GFCI to the neutral bar.
Manufacturer
Single
Double Twin
Quad
GFCB
Filler
Plates
Cutler-Hammer
BR
BR
BRD
BRD
GFCB
BRFP
Murray
MP-T
MP-T
MH-T
MH-T
MP-GT
LX100FP
Siemens
QP
QP
QT
QT
QPF
QF3
Square D
HOM
HOM
HOMT
HOMT
HOM
HOMFP
Thomas & Betts
TB
TB
TBBD
TBBQ
GFB
FP-1C-TB
SUITABLE LISTED BREAKERS
Field installed 20amp max breaker