45
Start Up: Configuration Parameters (cont’d)
FILTER PUMPS
Most configurations have a single filter pump, configured
as Filter Pump 1. A two-water-body, two-pump system has
two filter pumps, with Filter Pump 1 being the pool pump and
Filter Pump 2 the spa pump.
HEATERS
The system can support four types of heaters:
1. Gas
2. Electric Resistive (ER)
3. Heat Pump
4. Solar
Heaters are added to the system by configuring the
Heater 1, Heater 2, Heat Pump, Solar Valve, and Solar Boost
Pump devices.
Heater 1 is the main heater in the system. It can be Gas,
ER, or a Heat Pump. In a two-water-body two-pump system
Heater 1 is the pool heater.
Heater 2 is the spa heater in a two-water-body two-pump
system. It can be Gas, ER, or a Heat Pump.
Heat Pump is used to add a secondary Heat Pump in
addition to the main heater.
NOTE: If the Heat Pump is the main heater in the system,
it must be configured as Heater 1, not Heat Pump.
Solar Valve and Solar Boost Pump must be configured as
required to support a solar heat system. (See Page 46.)
NOTE: The solar heat system is only applicable to the pool
and cannot be used with a Spa Only system or on the Spa-
side of a two water body two pump system. In systems
containing both a pool and a spa, solar heat is only used
when the system is in Pool mode.
DEVICES
There are two types of devices: Pre-defined and Auxiliary.
Pre-defined devices have specific behaviors associated
with them and must be properly selected and configured
to operate correctly. Auxiliary devices are simple On/Off or
two-speed devices.
DEVICES THAT ARE PRE-DEFINED
Pool Light, Spa Light
: these are preconfigured to the
Light 1 and Light 2 triacs on the controller board, but can be
reassigned to any relay, valve, or triac.
Filter Pump 1
: this is automatically assigned to Relay 1.
If the pump is two-speed the second connection can be
assigned to any other relay on the main board.
Heater 1
: can be assigned to either the Low Voltage Heater
relay or any large relay for 120 volt systems.
Filter Pump 2, Heater 2
: these only apply to the two-water-
body two-pump configuration where there are two-filter-
pumps and heaters. They are not automatically assigned.
Cleaner
: controls an automatic pool cleaner. For a suction-
side cleaner, Cleaner must be assigned to the cleaner valve.
For a pressure-side cleaner, assign Cleaner to the boost
pump relay.
In-floor Cleaner
: the activation valve for an in floor cleaner.
In-floor Cleaner Boost Pump
: the optional booster pump for
an in-floor cleaner.
Pool Fill
: valve used to add water to the pool or spa.
Chlorine Generator
: preassigned to the Chlorine Generator
Control relay.
Note: In Heater display, Heater 2 will not show if it’s
not configured.
The configuration settings will automatically be set to operate according to a default specified by the DIP switch settings
prior to Start Up. Settings other than Day/Time and Filter Settings do not need to be configured for operation but should
be set for user preference. Configuration instructions for these items are not included in the Operation Manual.
DEVICE CONFIGURATION