Wiring Diagram for Integral Heater Version 

Hardware Setup

1

2

3

1

2

J4

J8

J18

J51

J1

J27

J10

3

J20

J10

J12

J88

J52

GRN

230V 

2/3þ 

2/3x16A

A2

A3

ON

OFF

A5

BLU

BRN 1

BRN 2

A8

A2

A3

ON

OFF

A5
A8

FOR PUMP2 OR BLOWER

ON HTR SERVICE (BRN 1):

J3 WIRE FROM EXPANDER

BOARD MUST BE 

WIRED TO AREA 2

FOR PUMP2 OR BLOWER

ON PUMP1 SERVICE (BRN 2):

J3 WIRE FROM EXPANDER 

BOARD MUST BE 

WIRED TO J55

BRN LINE 3

LINE 3 - CAP (INSULATE) END.

DO NOT CONNECT

J55

230V 

1x16A
1x32A

BRN

BLU

GRN

 

 

BRN

BLU

BRN 2

BRN 1

BLU

1 SERVICE 1X16A 1X32A 

2 OUT OF 3 SERVICE 2/3X16A

LOCATION DEVICE 

MAX AMPS

J9 

NETZSTROMVERSORGUNG 1/2-GESCHW.-PUMPE 1   

12A

 

ALIMENTATION POMPE 1 A 1/2 VITESSES  1/2-SPD PMP 1  MAX

J15 

10V BELEUCHTUNG  ECLAIRAGE BAIN HYDRO  SPA LIGHT 

1A (@10V) 

J19 

KREISLAUF PUMPE  POMPE DE CIRCULATION  CIRC PUMP 

2A MAX

J21 

OZONGENERATOR  GENERATOROZONE  OZONE GENERATOR 

0.5A MAX

J33 

TV / AV 

2A MAX

J11 & J13   HEATER 

 

 

 

  

     3.0 kW

SENSOR A

SENSOR B

3.0 kW HEATER

TORQUE RANGE FOR HEATER 

CONNECTIONS:  30 TO 35

IN. LBS. 

J3

PUMP 2

K1

J6

J2

W12

OPTIONAL EXPANDER X-P2151 PN 59233

LOCATION

DEVICE

VOLTS

AMPS

FROM

TO

FROM

TO

J6

PUMP 2

230V

12A

W12

AREA 3

J3

J55

CONNECT TO J55

CONNECT TO AREA 3

CONNECT TO J5

F5 15A 250V

EXPANDER

 X-B2151

EXPANDER X-B

J3

BLOWER

K1

J6

J2

W12

OPTIONAL EXPANDER X-B PN 59231

LOCATION

DEVICE

VOLTS

AMPS

FROM

TO

FROM

TO

J6

BLOWER

230V

 4A

W12

AREA 3

J3

J55

CONNECT TO J55

CONNECT TO AREA 3

CONNECT TO J5

F5 10A 250V

 

 

 

   

 

 

 

  1 

F POLLING 

1-SPEED  1-SPEED 

NONE 

X-P2151 (PN 59233) 

°C

 2 

NONE 

2-SPEED  1-SPEED 

NONE 

X-P2151 (PN 59233) 

°C

  3 

F POLLING 

1-SPEED 

NONE 

1-SPEED 

X-B (PN 59231) 

°C

 4 

NONE 

2-SPEED 

NONE 

1-SPEED 

X-B (PN 59231) 

°C

  5 

F POLLING 

1-SPEED 

NONE 

NONE 

NONE 

°C

 6 

NONE 

2-SPEED  NONE  NONE 

NONE 

°C

  7 

F POLLING 

NONE 

NONE 

NONE 

NONE 

°C

 SETUP # 

CIRC PUMP 

PUMP 1 

PUMP 2 

BLOWER 

USER-INSTALLED EXPANDER  TEMP SCALE

INSTEAD OF SETUP

#5, THIS SYSTEM

IS CONFIGURED

IN SETUP #:

TORQUE RANGE 

FOR TB1: 

27-30IN.LBS.

F4 1A SLO-BLOW

F5 1A SLO-BLOW

F3 0.1A SLO-BLOW

TB1

1

2

3

K5

K1

K2

K4

K3

F6 30A 250VAC

T1

J16

J17

J23

SERIAL

J5

REMOTE

RELAY

BOARD

J28 AUX FRZ

J35 MAIN

J34 MAIN

K7

K12

120V

120V

240V

J24

J9

PUMP 1

J19

CIRC

J21

OZONE

J33

A/V

1

2

J4

J8

J18

J55

J3

J6

J51

J1

J27

J110

J13

HEATER 1

J2

J7

3

J20

J10

J12

J88

J22

ON

S1

J31

J30

J109

J15

LIGHT

J52

J46

J38

J11

HEATER 2

TP (MAIN) PANELS

J34 OR J35

10-10-19

BP200UX PN 59340-01

1

8

FOR SUPPLY CONNECTIONS, 

USE CONDUCTORS SIZED ON THE 

BASIS OF 60°C AMPACITY BUT 

RATED MINIMUM OF 90°C.

USE COPPER CONDUCTORS ONLY.

EMPLOYER UNIQUEMENT 

DES CONDUCTEURS DE CUIVRE.  

#6 AWG MIN. WIRE= 90°  

TOTAL OUTPUT AMP DRAW NOT TO 

EXCEED MAX INPUT RATING OF SPA

USE EARTH GROUND CONNECTIONS 

AS INDICATED INSIDE SYSTEM ENCLOSURE

WIFI

TRANSCEIVER

J34 OR J35

NOTE:  SWITCH A7
SHOULD BE OFF IF
USING WIFI, SINCE
WIFI DOESN’T SUPPORT
SIMPLIFIED MENUS.

 

 

 

   

 

ALL UNUSED SWITCHES SHOULD BE OFF

8
7
6
5
4
3
2
1

OFF POSITION  

S1 SWITCH #

ON POSITION

*SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION.

NOTE:  SWITCH A7 MUST BE OFF WHEN USING GRAPHIC
PANELS (TP800, TP900, OR SPATOUCH FAMILY).

3-PHASE SPCL AMP RULE OFF
STANDARD MENUS
STORE SETTINGS*
SPECIAL AMPERAGE RULE OFF
1 MIN HTR COOLDOWN (ELEC)
DON’T ADD 2 HS PUMPS W/HTR
DON’T ADD 1 HS PUMP W/HTR
TEST MODE OFF

3-PHASE SPCL AMP RULE ON
SIMPLIFIED MENUS
MEMORY RESET*
SPECIAL AMPERAGE RULE ON
5 MIN HTR COOLDOWN (GAS)
ADD 2 HS PUMPS WITH HEAT
ADD 1 HS PUMP WITH HEAT
TEST MODE ON

EXPANDER BOARD MOUNTING HARDWARE
IS PRE-INSTALLED ON THIS MODEL.

NO EXPANDER BOARD IS USED
IN SEtUPS 5 - 7.

230V 

1x32A

A2

A5

ON

OFF

230V 

1x16A

Summary of Contents for 59340-01

Page 1: ...ID M100_235 V52 0 Software Version 52 0 File Name BP200_52 0_BP200UX hex Configuration Signature AE7D76E4 Eng Project Number 5270 Control Panels See later pages for more information spaTouch 2 Any ver...

Page 2: ...with an optional user insstalled expander board the expander board mounting hardware is pre installed 59340 01 59342 01 5270 09 05 19 BWG Update software for full TP500 compatibility 59310 5270 09 05...

Page 3: ...of the three lines unused The third line could be used for a slave heater if desired or left for a use not related to the spa at all BP systems automatically detect 50Hz vs 60Hz However power frequenc...

Page 4: ...mp at high speed prevents you from turning the other pump to high speed You have to turn the first pump to either low speed or OFF before you can turn the other pump to high speed 2 out of 3 Service w...

Page 5: ...P1 Low in non circ Setupa 2 4 6 only This is the heater pump in Setups 2 4 6 Must deliver 20 GPM through heater 1 Speed in Setups 1 3 5 Unused in Setup 7 Pump 2 230VAC 1 Speed 12A max 15 minute timer...

Page 6: ...AREA 3 CONNECT TO J5 F5 10A 250V 1 FILTERS POLLING 1 SPEED 1 SPEED NONE X P2151 PN 59233 C 2 NONE 2 SPEED 1 SPEED NONE X P2151 PN 59233 C 3 FILTERS POLLING 1 SPEED NONE 1 SPEED X B PN 59231 C 4 NONE 2...

Page 7: ...ING 1 SPEED 1 SPEED NONE X P2151 PN 59233 C 2 NONE 2 SPEED 1 SPEED NONE X P2151 PN 59233 C 3 FILTERS POLLING 1 SPEED NONE 1 SPEED X B PN 59231 C 4 NONE 2 SPEED NONE 1 SPEED X B PN 59231 C 5 FILTERS PO...

Page 8: ...A2 A5 ON OFF 230V 1 1x16A As shown on additional wiring diagram sections 1 2 J4 J8 J18 J51 J1 J27 J10 3 J20 J10 J12 J88 J52 230V 2 3 2 3x16A A2 A3 ON OFF A5 A8 A2 A3 ON OFF A5 A8 FOR PUMP2 OR BLOWER O...

Page 9: ...o Change Software Setups While in Test Mode press the indicated icons to move from screen to screen ON 1 10 S1 Changing Software Setups with spaTouch Icon Driven Panels Once on the Setup Selection scr...

Page 10: ...em is running move DIP Switch 1 on S1 on the Main circuit board to ON The system will enter Test Mode Moving DIP Switch 1 to OFF will exit Test Mode Software Setups Under the TEST Menu the Setup scree...

Page 11: ...oving DIP Switch 1 to OFF will exit Test Mode Software Setups Under the TEST Menu the Setup screen will allow changing the Setup from 1 to any number established by the Manufacturer Changing the Setup...

Page 12: ...ace a circuit board or system and needs to change the Setup on a replacement part while in the field NOTE Changing the Setup may require wiring changes as well refer to the wiring diagram or wiring di...

Page 13: ...188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending Copyright 2009 Balboa Water Group Expansion F...

Page 14: ...etermined by software configuration A2 and A3 work in combination to determine the number of high speed devices and blowers that can run before the heat is disabled i e A2 and A3 in the ON position wi...

Page 15: ...models J30 Do Not Use J31 Jumper on 1 pin with 2 0kW or smaller heater Jumper on 2 pins with a 3 0kW or higher heater J44 Jumper must be on center two pins 240V for CE Systems Warning Setting DIP swi...

Page 16: ...9341 01 3 0kW Models 59343 01 2 0kW Models Remote Model Expander PCBA 59233 X P2151 for Pump2 59231 X B for Blower HEATER s Heater 58419 3 0kW 800 Inc for integral heater only 58450 3 0kW 825 Inc for...

Page 17: ...nly General Pump Timer 15 Minutes Blower Timer 15 Minutes Mister Timer 15 Minutes Light Timer 240 Minutes Circ when enabled Programmable Polling Circ Pump can be set with the following functions 24 hr...

Page 18: ...ired for default settings choose a desired C value that after rounding cor responds to a Fahrenheit value C 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 F 39 41 43 45 46 48 50 52 54 55 57 59 61...

Page 19: ...me Format 24 Hour 12 Hour 24 Hour N A Filter 1 Start Hour 20 00 8 00 PM 00 00 to 23 00 1 Hour Filter 1 Duration 2 Hours Between 15 Min and 23 45 15 Minutes or continuous Filter Cycle 2 Default OFF OFF...

Page 20: ...ment Reminders Shown Yes Yes No N A Check pH OFF See Reminder Period Note 1 Days Check Sanitizer OFF See Reminder Period Note 1 Days Clean Filter 30 Days See Reminder Period Note 1 Days Test GFCI OFF...

Page 21: ...B 1 Pump at High Speed maximum Blower turns OFF when 1 Pump is at High Speed 3 Phase Special Amperage Rule Pumps or Blower in Group 3 eg Pump 2 are the only ones which turn the Heater Off Pumps not in...

Page 22: ...ert Invert Circ Icon 5 Invert Invert Invert Invert Circ Icon Undefined Undefined 6 Circ Icon Undefined Circ Icon Undefined Undefined Undefined Undefined 7 Undefined Undefined Undefined Undefined Undef...

Page 23: ...Icon Undefined A6 Circ Icon Undefined Circ Icon Undefined Undefined Undefined A7 Undefined Undefined Undefined Undefined Undefined Undefined A8 Undefined Undefined Undefined Undefined Undefined Undef...

Page 24: ...976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending Copyright 2009 Balboa Water Group TP800 Panel Conf...

Page 25: ...domestic applied for and pending Copyright 2009 Balboa Water Group TP600 Panel Configuration READY RANGE FLTR1 1 2 3 4 5 6 1 2 3 4 1 2 3 4 1 4 2 5 3 6 TP600 55676 XX No Overlay Button Layout Table Bu...

Page 26: ...260 XX Includes overlay PN 12511 Button Layout Table for TP400T Button Setups 1 2 Setups 3 4 Setups 5 6 Setup 7 1 Temperature Temperature Temperature Up 2 Jets 1 Jets 1 Jets 1 Down 3 Light 1 Light 1 L...

Reviews: