Wiring Diagram for Remote Heater Version
Hardware Setup
1
2
3
1
2
J4
J8
J18
J51
J1
J27
J10
3
J20
J10
J12
J88
J52
GRN
230V
2/3þ
2/3x16A
A2
A3
ON
OFF
A5
BLU
BRN 1
BRN 2
A8
A2
A3
ON
OFF
A5
A8
FOR PUMP2 OR BLOWER
ON HTR SERVICE (BRN 1):
J3 WIRE FROM EXPANDER
BOARD MUST BE
WIRED TO AREA 2
FOR PUMP2 OR BLOWER
ON PUMP1 SERVICE (BRN 2):
J3 WIRE FROM EXPANDER
BOARD MUST BE
WIRED TO J55
BRN LINE 3
LINE 3 - CAP (INSULATE) END.
DO NOT CONNECT
J55
230V
1þ
1x16A
1x32A
BRN
BLU
GRN
BRN
BLU
BRN 2
BRN 1
BLU
1 SERVICE 1X16A 1X32A
2 OUT OF 3 SERVICE 2/3X16A
LOCATION DEVICE
MAX AMPS
J9
NETZSTROMVERSORGUNG 1/2-GESCHW.-PUMPE 1
12A
ALIMENTATION POMPE 1 A 1/2 VITESSES 1/2-SPD PMP 1 MAX
J15
10V BELEUCHTUNG ECLAIRAGE BAIN HYDRO SPA LIGHT
1A (@10V)
J19
KREISLAUF PUMPE POMPE DE CIRCULATION CIRC PUMP
2A MAX
J21
OZONGENERATOR GENERATOROZONE OZONE GENERATOR
0.5A MAX
J33
TV / AV
2A MAX
J11 & J13 HEATER
SENSOR A
SENSOR B
REMOTE HEATER*
TORQUE RANGE FOR HEATER
CONNECTIONS: 30 TO 35
IN. LBS.
*REMOTE HEATER
SOLD SEPARATELY
EXPANDER
X-B2151
J3
PUMP 2
K1
J6
J2
W12
OPTIONAL EXPANDER X-P2151 PN 59233
LOCATION
DEVICE
VOLTS
AMPS
FROM
TO
FROM
TO
J6
PUMP 2
230V
12A
W12
AREA 3
J3
J55
CONNECT TO J55
CONNECT TO AREA 3
CONNECT TO J5
F5 15A 250V
EXPANDER X-B
J3
BLOWER
K1
J6
J2
W12
OPTIONAL EXPANDER X-B PN 59231
LOCATION
DEVICE
VOLTS
AMPS
FROM
TO
FROM
TO
J6
BLOWER
230V
4A
W12
AREA 3
J3
J55
CONNECT TO J55
CONNECT TO AREA 3
CONNECT TO J5
F5 10A 250V
1
F POLLING
1-SPEED 1-SPEED
NONE
X-P2151 (PN 59233)
°C
2
NONE
2-SPEED 1-SPEED
NONE
X-P2151 (PN 59233)
°C
3
F POLLING
1-SPEED
NONE
1-SPEED
X-B (PN 59231)
°C
4
NONE
2-SPEED
NONE
1-SPEED
X-B (PN 59231)
°C
5
F POLLING
1-SPEED
NONE
NONE
NONE
°C
6
NONE
2-SPEED NONE NONE
NONE
°C
7
F POLLING
NONE
NONE
NONE
NONE
°C
SETUP #
CIRC PUMP
PUMP 1
PUMP 2
BLOWER
USER-INSTALLED EXPANDER TEMP SCALE
INSTEAD OF SETUP
#5, THIS SYSTEM
IS CONFIGURED
IN SETUP #:
TORQUE RANGE
FOR TB1:
27-30IN.LBS.
F4 1A SLO-BLOW
F5 1A SLO-BLOW
F3 0.1A SLO-BLOW
TB1
1
2
3
K5
K1
K2
K4
K3
F6 30A 250VAC
T1
J16
J17
J23
SERIAL
J5
REMOTE
RELAY
BOARD
J28 AUX FRZ
J35 MAIN
J34 MAIN
K7
K12
120V
120V
240V
J24
J9
PUMP 1
J19
CIRC
J21
OZONE
J33
A/V
1
2
J4
J8
J18
J55
J3
J6
J51
J1
J27
J110
J13
HEATER 1
J2
J7
3
J20
J10
J12
J88
J22
ON
S1
J31
J30
J109
J15
LIGHT
J52
J46
J38
J11
HEATER 2
TP (MAIN) PANELS
J34 OR J35
10-10-19
BP200UX PN 59310
1
8
FOR SUPPLY CONNECTIONS,
USE CONDUCTORS SIZED ON THE
BASIS OF 60°C AMPACITY BUT
RATED MINIMUM OF 90°C.
USE COPPER CONDUCTORS ONLY.
EMPLOYER UNIQUEMENT
DES CONDUCTEURS DE CUIVRE.
#6 AWG MIN. WIRE= 90°
TOTAL OUTPUT AMP DRAW NOT TO
EXCEED MAX INPUT RATING OF SPA
USE EARTH GROUND CONNECTIONS
AS INDICATED INSIDE SYSTEM ENCLOSURE
J31
2.0 kW
J31
J31 JUMPER MUST BE ON 1 PIN WITH 2.0 KW HEATER,
BUT ON 2 PINS WITH 3.0 KW HEATER.
3.0 kW
(AS MANUFACTURED)
WIFI
TRANSCEIVER
J34 OR J35
NOTE: SWITCH A7
SHOULD BE OFF IF
USING WIFI, SINCE
WIFI DOESN’T SUPPORT
SIMPLIFIED MENUS.
ALL UNUSED SWITCHES SHOULD BE OFF
8
7
6
5
4
3
2
1
OFF POSITION
S1 SWITCH #
ON POSITION
*SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION.
NOTE: SWITCH A7 MUST BE OFF WHEN USING GRAPHIC
PANELS (TP800, TP900, OR SPATOUCH FAMILY).
3-PHASE SPCL AMP RULE OFF
STANDARD MENUS
STORE SETTINGS*
SPECIAL AMPERAGE RULE OFF
1 MIN HTR COOLDOWN (ELEC)
DON’T ADD 2 HS PUMPS W/HTR
DON’T ADD 1 HS PUMP W/HTR
TEST MODE OFF
3-PHASE SPCL AMP RULE ON
SIMPLIFIED MENUS
MEMORY RESET*
SPECIAL AMPERAGE RULE ON
5 MIN HTR COOLDOWN (GAS)
ADD 2 HS PUMPS WITH HEAT
ADD 1 HS PUMP WITH HEAT
TEST MODE ON
EXPANDER BOARD MOUNTING HARDWARE
IS PRE-INSTALLED ON THIS MODEL.
NO EXPANDER BOARD IS USED
IN SEtUPS 5 - 7.
230V
1þ
1x32A
A2
A5
ON
OFF
230V
1þ
1x16A