background image

42256_A

01-09-14

10

Manufactured under one or more of these patents.  U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2, 
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.   All material copyright of Balboa Water Group.

Preparation and Filling

Fill the spa to its correct operating level. Be sure to open all valves and jets in the plumbing system before filling to allow 
as much air as possible to escape from the plumbing and the control system during the filling process.

After turning the power on at the main power panel, the top-side panel will display a splash screen or startup screen.

Priming Mode – M019*

After the initial start-up sequence, the control will enter Priming Mode and display a Priming Mode screen. Only pump icons 
appear on the priming mode screen. During the priming mode, the heater is disabled to allow the priming process to be 
completed without the possibility of energizing the heater under low-flow or no-flow conditions. Nothing comes on auto-
matically, but the pump(s) can be energized by selecting the “Jet” buttons.  If the spa has a Circ Pump, it can be turned on 
and off by pressing the “Circ Pump” button during Priming Mode. 

Priming the Pumps

As soon as the Priming Mode screeen appears on the panel, select the 
“Jets 1” button once to start Pump 1 in low-speed and then again to 
switch to high-speed. Also, select the other pumps, to turn them on. 
The pumps should be running in high-speed to facilitate priming. If 
the pumps have not primed after 2 minutes, and water is not flowing 
from the jets in the spa, do not allow the pumps to continue to run. 
Turn off the pumps and repeat the process. Note: Turning the power off 
and back on again will initiate a new pump priming session. Sometimes 
momentarily turning the pump off and on will help it to prime. Do not 
do this more than 5 times. If the pump(s) will not prime, shut off the 
power to the spa and call for service.

Important: A pump should not be allowed to run without priming for more than 2 minutes. Under NO circumstances should 
a pump be allowed to run without priming beyond the end of the 4-5 minute priming mode. Doing so may cause damage to 
the pump and cause the system to energize the heater and go into an overheat condition. 

Exiting Priming Mode

The system will automatically enter the normal heating and filtering at the end of the priming mode, which lasts 4-5  
minutes. 

You can manually exit Priming Mode by pressing the “Exit” button on the Priming Mode Screen. Note that if you do not 
manually exit the priming mode as described above, the priming mode will be automatically terminated after 4-5 minutes. 
Be sure that the pump(s) have been primed by this time. 

Once the system has exited Priming Mode, the top-side panel will display the Main Screen, but the display will not show the 
temperature yet, as shown below. This is because the system requires approximately 1 minute of water flowing through the 
heater to determine the water temperature and display it.

Fill it up!

Priming Mode

Exit

Jets 1

Jets 2

Jets 3

Circ

– – –°F

– – –°C

*M0XX is a Message Code. See Fault Log on Page 17. 

Summary of Contents for BP Series

Page 1: ...a Water Group spaTouch Menued Control Panels Balboa Water Group BP Series Systems User Interface and Programming Reference The spaTouch menued panel is compatible with all BP systems that already supp...

Page 2: ...features including Set Temperature adjustment can be accessed from this screen The actual water temperature and Set Temperature can be seen and the Set Temperature can be adjusted see page 4 Time of D...

Page 3: ...t is selectable The menu selections on the right side of the screen can be selected Select one of these to enter a different screen with additional controls Most menu screens time out and revert to th...

Page 4: ...other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group The Set Temperature Screen Set Set Temperature 101 F High Range Back Dec Inc Set Temperatur...

Page 5: ...ent installed on a particular spa model so this screen may change depending on the installation The icon buttons are used to select and control individual devices Some devices like pumps may have more...

Page 6: ...e labeled or not they always mean Save and Cancel They appear on most editing screens once you have changed the value on that screen If the screen times out due to no activity it will act like Cancel...

Page 7: ...Day Filter Cycles Light Cycle Invert Panel Lock High Ready Normal Page Up Down If an Up or Down button is shown and pressed when in a Menu List the list can be scrolled a page at a time The scroll ba...

Page 8: ...pointing to the right go to another level in the menu Settings Back Temp Range Heat Mode Time of Day Filter Cycles Light Cycle Invert Panel Lock High Ready Normal Dual Temperature Ranges High vs Low T...

Page 9: ...until the heater pump has been running for a minute or two When the heater pump has come on automatically for example for heating you can switch between low speed and high speed but you cannot turn th...

Page 10: ...em on The pumps should be running in high speed to facilitate priming If the pumps have not primed after 2 minutes and water is not owing from the jets in the spa do not allow the pumps to continue to...

Page 11: ...The speci c Circulation Mode that is used has been determined by the Manufacturer and cannot be changed in the eld Other device options may be available like Blower Light Mister etc Filtration and Oz...

Page 12: ...e of Day Be sure to set the Time of Day Setting the time of day is important for determining ltration times and other background features Set Time will appear on the display if no time of day is set i...

Page 13: ...t allow programming ltration cycle duration Some circ Modes are pre programmed to operate 24 hours a day and are not programmable Refer to the spa manufacturer s documentation for any Circ Mode detail...

Page 14: ...Light Timer is OFF by default The settings can be edited the same way that Filter Cycles are edited see page 13 Speci c Buttons for Speci c Devices If the spa has an Auxiliary Panel s installed press...

Page 15: ...event unwanted use or temperature adjustments Locking the Panel prevents the controller from being used but all automatic functions are still active Locking the Settings allows Jets and other features...

Page 16: ...ng any Scene line which has not yet been stored will simply turn off all spa devices Scenes Scene 1 Scene 2 Scene 3 Scene 4 Back Scene stored What are Scenes Scenes are stored combinations of equipmen...

Page 17: ...s enabled so it may not appear This is designed to operate several devices in a sequence in order to demonstrate the various features of a particular hot tub Fault Log The Fault Log is a record of the...

Page 18: ...nd 24 hr display Reminders Turn the reminder messages like Clean Filter On or Off Cleanup Cleanup Cycle Duration is not always enabled so it may not appear When it is available set the length of time...

Page 19: ...ystem Model Displays the Model Number of the System Current Setup Displays the currently selected Con guration Setup Number Con guration Signature Displays the checksum for the system con guration le...

Page 20: ...oblem Forcing the GFCI Trip Test North America Only The installer can cause the GFCI Trip Test to occur sooner by initiating it using the above menu The GFCI should trip within several seconds and the...

Page 21: ...is too hot M029 The system has detected a spa water temp of 110 F 43 3 C or more and spa functions are disabled System will auto reset when the spa water temp is below 108 F 42 2 C Check for extended...

Page 22: ...it The spa is shut down for 15 min Reset this message to reset the heater start up See Flow Related Checks below The heater is dry M027 There is not enough water in the heater to start it The spa is...

Page 23: ...ensors ARE out of sync The fault above has been established for at least 1 hour Call for Service Sensor A Fault Senor B Fault Sensor A M031 Sensor B M032 A temperature sensor or sensor circuit has fai...

Page 24: ...Only May indicate an unsafe installation Contact your dealer or service organization Hot fault M035 A Pump Appears to have been Stuck ON when spa was last powered POWER DOWN THE SPA DO NOT ENTER THE...

Page 25: ...ater chemistry with a test kit and adjust with the appropriate chemicals Clean the lter May appear on a regular schedule i e every 30 days Clean the lter media as instructed by the manufacturer See HO...

Page 26: ...RCD will have a TEST and RESET button on it that allows a user to verify proper function Additional messages may appear on speci c systems Change the water May appear on a regular schedule i e every 9...

Page 27: ...THE INSTRUCTION MANUAL s DEQUATE DRAINAGE MUST BE PROVIDED IF THE EQUIPMENT IS TO BE INSTALLED in a pit s OR USE ONLY WITHIN AN ENCLOSURE RATED 3 NCLOSURE s ONNECT ONLY TO A CIRCUIT PROTECTED BY A LAS...

Page 28: ...18 Fault Log 17 Filter 2 filter cycle 11 13 Flow Related Checks 22 Freeze Protection 8 11 21 G GFCI 27 GFCI Test 17 20 H Heat Mode 9 High Range 8 Hold 17 I Information 19 L Language 18 Light Cycle 14...

Reviews: