Special Features
Feature
Default Options
Increment
Special Amperage Rule A
No Limitation
1 Pump
Special Amperage Rule B
No Limitation
1 Pump
1 to 7 pumps can run on high speed together.
Blower can be allowed or suppressed when number of pumps selected is reached.
“No Limitation” does not restrict pump or blower operation.
DIP Switch 5 is used to choose Special Amperage Rule 1 or 2.
Drain Mode
Disabled
Disabled, Enabled
N/A
Demo Mode
Disabled
GFCI Trip
Enabled
Disabled, Enabled
N/A
Automatic GFCI Test
Disabled
Disabled, 1-7 Days
1 Day
When GFCI Test is Enabled, the Auto-Test can be set between 1 and 7 days from startup
Ozone Slaved to Heater Pump
Yes
Yes, No
N/A
Dual Voltage Heater
Always Input Voltage
4°F Temperature Delta
N/A
Safety Suction
Disabled
Disabled, Enabled
N/A
Menu Style
Standard Menus when DIP switch A7 is OFF.
Simplified Menus when DIP switch A7 is ON..
BP100 Configuration Options