Optional Heaters
The Remote Heaters are supplied with a 60” cord which allows for versatile installations
and locations with multiple angles. BE SURE HEATER IS INSTALLED ON PRESSURE
SIDE OF PUMP.
HEATER MUST BE BONDED TO THE CONTROL BOX USING A #8 SOLID COPPER
BONDING WIRE (NOT INCLUDED).
Optional Cords
Cord Adapters are available which allow you to quickly replace a control system without
changing the original cords . These cord adapters allow you to take a 4-pin amp style plug
from the component and quickly convert it to the molded mini plug for the control system,
saving you hours of install time.
10
30-1220-L6
30-1180-L6
The Hydro-Quip Lite-Leader sensor kit has been developed to offer the maximum in
flexibility. Unlike the traditional sensor kit, Hydro-Quip has separated the sensors to allow
them to be replaced independently. It is important to connect the sensor(s) to the correct
position(s) on the PCB. Please refer to the photo above for the correct connection points.
Temperature Sensor Connections
Pressure Switch
High-Limit Temp Sensor
1/4” Bulb 3/8” or 1/4” Bulb
It is important to connect the sensor(s) to the correct position(s) on the
PCB. Please refer to the photo above for the correct connection points.
SPASIDE
HIGH-LIMIT
TEMPERA
TURE
3
1
2
4
3
1
2
4
SpaDepot.com