Setup Changes with DIP Switch 1 ON

As soon as Switch #1 is placed 
in the ON position,
The temperature will show
“T” after it instead of F or C, 
indicating the System is
in Test Mode

1

S1

6

J17
J16

J29 VAC

J28 AUX FRZ

ON

DANGER! HIGH VOLTAGE WILL BE ACCESSIBLE! 
SERVICE TECHNICIAN ONLY!

Move DIP Switch 1 (on S1 on the Logic circuit 
board) to ON. 
The system will enter Test Mode. 
Moving DIP Switch 1 to OFF will exit Test Mode.

Read and understand these instructions before beginning this process.

Know the Setup Number you want before you power up the spa and wait to power up the spa until you’re ready to change 
the Setup Number.  

The system must be in Test Mode, so move Switch 1 to the ON position. The Test Menu will then be available.

Power up the spa, and press any button once to Link the panel. (Note: Switch 1 can be moved to the ON position immedi-
ately after power-up, if preferred - Danger! High Voltage will be present!)

You will have 1 minute 

to complete the setup change after you manually exit Priming Mode. (Once familiar with the pro-

cess, the Setup change should take less than 15 seconds.)

When the panel displays RUN PMPS PURG AIR, press any Temperature button ONCE to exit Priming Mode.  
You should see “---T” where the T indicates the system is in Test Mode.

Continued on Next Page.

READY

RANGE

Summary of Contents for BP600

Page 1: ...3kW 800 Incoloy Heater Element 56282 3kW 825 Incoloy Heater Element 56283 3kW Titanium Heater Element CE System Model BP16 BP600 RCA 3 0KW Software ID M100_205 V6 Software Version 6 0 Hex File BP1600_...

Page 2: ...s hot hot optional neutral ground H 240VAC 60Hz 32A Class A GFCI protected service Circuit Breaker 40A max 4 wires hot hot neutral ground F 120VAC 60Hz 16A Class A GFCI protected service Circuit Break...

Page 3: ...BLOCK TB1 27 30 IN LBS 31 1 34 5 kg cm USE COPPER CONDUCTORS ONLY EMPLOYER UNIQUEMENT DES CONDUCTEURS DE CUIVRE L2 L1 N F3 10A 250V F2 3A 250V T 150mA 250V F6 J44 J48 J1 J2 J24 J45 J49 J15 J16 J47 J1...

Page 4: ...IMUM OF 90 C TORQUE RANGE FOR MAIN TERMINAL BLOCK TB1 27 30 IN LBS 31 1 34 5 kg cm USE COPPER CONDUCTORS ONLY EMPLOYER UNIQUEMENT DES CONDUCTEURS DE CUIVRE L2 L1 N F3 10A 250V F2 3A 250V T 150mA 250V...

Page 5: ...the original Setup 1 default J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED WS02CE FOR SUPPLY CONNECTIONS USE CONDUCTORS SIZED ON THE BASIS OF 60 C AMPACITY BUT RATED MINIMUM OF 90 C TOR...

Page 6: ...on Add 1 High Speed Pump with Heat DIP Switch 2 OFF DIP Switch 2 ON Blue indicates changes from the original Setup 1 default J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED WS02CE FOR SUP...

Page 7: ...nal Setup 1 default J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED WS03CE FOR SUPPLY CONNECTIONS USE CONDUCTORS SIZED ON THE BASIS OF 60 C AMPACITY BUT RATED MINIMUM OF 90 C TORQUE RANGE...

Page 8: ...with Heat DIP Switch 2 OFF DIP Switch 2 ON Blue indicates changes from the original Setup 1 default J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED WS03CE FOR SUPPLY CONNECTIONS USE COND...

Page 9: ...d Blue indicates changes from the original Setup 1 default J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED WS04CE FOR SUPPLY CONNECTIONS USE CONDUCTORS SIZED ON THE BASIS OF 60 C AMPACITY...

Page 10: ...Not Used non circ Circ Pump Enabled J2 J32 Hot Output Useable Blue indicates changes from the original Setup 1 default J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED WS04CE FOR SUPPLY C...

Page 11: ...lt J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED WS05CE FOR SUPPLY CONNECTIONS USE CONDUCTORS SIZED ON THE BASIS OF 60 C AMPACITY BUT RATED MINIMUM OF 90 C TORQUE RANGE FOR MAIN TERMINA...

Page 12: ...ot Output Useable Blue indicates changes from the original Setup 1 default J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED FOR SUPPLY CONNECTIONS USE CONDUCTORS SIZED ON THE BASIS OF 60 C...

Page 13: ...s from the original Setup 1 default J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED WS06CE FOR SUPPLY CONNECTIONS USE CONDUCTORS SIZED ON THE BASIS OF 60 C AMPACITY BUT RATED MINIMUM OF 9...

Page 14: ...on Add 1 High Speed Pump with Heat DIP Switch 2 OFF DIP Switch 2 ON Blue indicates changes from the original Setup 1 default J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED FOR SUPPLY CON...

Page 15: ...will enter Test Mode Moving DIP Switch 1 to OFF will exit Test Mode Read and understand these instructions before beginning this process Know the Setup Number you want before you power up the spa and...

Page 16: ...nually exit Priming Mode Immediately after exiting Priming Mode press this sequence of buttons Warm Light Warm Warm Warm Warm Continue to press Warm until the diplay shows the Setup Number S 01 S 02 e...

Page 17: ...wer and heater runs on service line L1 with L2 acting as the return 230VAC Set the DIP switches according to the wiring diagram so that total system current draw never exceeds the rated service input...

Page 18: ...s etc Requires a single speed P1 Cleanup Cycle 30 Minutes Between 30 and 240 minutes 30 Minutes or OFF Cleaup as Preference setting Yes Yes No N A Ozone With Heater Pump Always Filters Cleanup Only N...

Page 19: ...Default Temp 70 F Between 50 and 99 F 1 F Freeze Threshold 44 F Between 39 and 54 F 1 F Temp Lock Type Temp Settings Temp Temp Settings N A Time Features Feature Default Options Increment Time Format...

Page 20: ...number of pumps selected is reached No Limitation does not restrict pump or blower operation DIP Switch 5 is used to choose Special Amperage Rule 1 or 2 Drain Mode Disabled Disabled Enabled N A Demo M...

Page 21: ...s 3 Jets 4 Jets 5 Jets 6 Jets 7 Jets 8 Blower 1 Blower 2 Mister 1 Mister 2 Mister 3 Light 1 Light 2 Light 3 Light 4 Fiber Optic Option 1 Option 2 Option 3 Option 4 EitherLight Configuration Options TP...

Page 22: ...ons Unused Heat On Filter Cycle On Lock Jets 1 Jets 2 Jets 3 Jets 4 Jets 5 Jets 6 Jets 7 Jets 8 Blower 1 Blower 2 Mister 1 Mister 2 Mister 3 Light 1 Light 2 Light 3 Light 4 Fiber Optic Option 1 Option...

Page 23: ...Down Temp Jets 1 Jets 2 Jets 3 Jets 4 Jets 5 Jets 6 Jets 7 Jets 8 Blower 1 Blower 2 Mister 1 Mister 2 Mister 3 Light 1 Light 2 Light 3 Light 4 Fiber Optic Option 1 Option 2 Option 3 Option 4 EitherLig...

Reviews: