background image

Page 5

EL1500 - 40916_01_C

TORQUE 
RANGE
FOR TB1:
27-30 IN. LBS.

H

OT

BLA

C

K

NEUTRAL

W

HITE

H

O

T

R

ED

K6

K13

K4

K2

K3

W

HT A

C

BLK AC

J61

J62

J11

J66 J6

5

J1

5

J16

J2

5

J63 J64

C

LA

SS

 G

F

USE 30

A

F

5

TB1

HTR2

HTR1

J101

F2

J100

B

al

boa

SWITCHBANK A

S1

J6

J7

J8

J13

J44

J60

J22

E.GN

D

1 SP. EXT. RLY

TST

CFG

AUX. F

SEN. A

SEN. B

W10

VAC

RED AC

J32 J33 J34

J36

J37

J3

5

T1

FUSE .3A 2

5

0V

F4

E

L1

5

00

P

/N  2207

5

_B

CO

PYRIGHT 2008

G

C

K1

J1

J2

J23

J74

J48

J46

W1

J

5

0

J17

G

C

W4

G

C

W7

2-SP
EXT RLY

FUSE 20A 2

5

0V

K8

K9

F8

G

C

G

C

J2

0

J4

5

J29

J47

W2

J69

J70

W3

FUSE 3A 2

5

0

V

F1

G

C

U4

K

5

J71

ADCM

MAIN
PANEL

MAIN ML PNL

R

EM

O

T

E

J8

2

J12

J3

For 120V Systems, 
DIP A2 and A3 must be OFF 
and Jumper Wire added.

5

.

5

 kW

Heater rated @ 240V
(Approx. 1.4kW @ 120V)

Audio VisualAudio Visual

Do not remove Fuse F8 (20A)

12V 

Light

G

R

B

W

J1

W1

J7

J6

F30A 480V

X-P332
PN 

55

137

P/N 22909 REV B

Not Used

Ozone

C

onfiguration 

Settings 
Enabled

2-Spd P1

Real-Time 

C

lock Board

NOT Installed

Wiring Configuration and DIP Settings

Setup 1 (As Manufactured)

s 60UMP3PEED
s 60UMP3PEED
s 6"LOWER3PEED

s 6#IRC0UMP
s 63PA,IGHT
s 6/ZONE

s 6!<6

(Stereo)

s 6K7(EATER
s -,-AIN0ANEL

Switchbank A

A4, Filters by Time

A6, 

A5, 

A8, 
A9, Filter Duration 2 hr.

A7, 

A11, Special Amp Rule OFF
A12, Memory ON

A10, No Edit

When the Logic Jumper is installed on J82 (CFG),
Software Config. Settings are enabled. 
DIP Switches will operate as shown.

}

See Table 2
Circ Behavior

 Pumps w/Heat

See Table 1

}

See Table 3
Pump 2

}

CFG

J2

J82

100
114

35

SSID #

120 Volt Connections

240 Volt Connections

Black AC Jumpers 

12 Volt Connections

Relay Control Wires

Wiring Color Key

Typically Line voltage

Typically Line voltage for 2-speed pumps

Neutral (Common)

Ground

Note flat sides in connector

1

2

3

4

Board Connector Key

WARNING: 

Main Power to system should be turned OFF BEFORE adjusting DIP switches.

WARNING: 

Persistent Memory (A12) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)

Indicate DIP positions needed for this system.

Special Connections/Notes:________________ 

________________________________________ 

________________________________________

Expander Boards 

(Select configuration)

Device

Ex Board Model

Voltage

Blower (2/3-Spd)

X-B

120V

Pump 3 - 1 Spd

X-TB

240V

Pump 4 - 1 Spd

X-P

Mister

X-P231

ADCM Splitter

X-P332

Cables\Adapters

PS-34

H

 Ozone on J17

H

 Ozone on J29

H

 Include Real-Time Clock capability 

Summary of Contents for EL1500 v35

Page 1: ...Panels AX40 PN 54527 AX10 X _____________ System PN ________ System Model E2P ______ _CA_ EL1500 Tech Sheet v35 Template This is not a shippable model This document template is merely a starting point...

Page 2: ...stem PN EPN Date Requested By Changes Made This page is for listing the changes made to this system and will be filled in as the tech sheet are created updated This will provide a quick reference of w...

Page 3: ...R ODULE Connects to Remote terminal J20 s UXILIARY 0ANEL ONNECTIONS AND s ZONE ENERATOR Connects to terminal J29 or J17 s OOD 8 IGHTING Connects to Spa Light terminal J12 s 3TEREO 3YSTEM Connects to A...

Page 4: ...m For example s h would mean that the combination of how you ve set A5 and how you ve set B2 is not supported on this system s h v WOULD MEAN THAT THERE IS A PROBLEM WITH JUMPER s h would mean that th...

Page 5: ...ONE s 6 6 Stereo s 6 K7 EATER s AIN 0ANEL Switchbank A A4 Filters by Time A6 A5 A8 A9 Filter Duration 2 hr A7 A11 Special Amp Rule OFF A12 Memory ON A10 No Edit When the Logic Jumper is installed on J...

Page 6: ...y reset used when spa is powering up See Persistent Memory and Powering Up page CFE errors are illegal configurations such as a pump and a blower set to run on the same output The configuration must b...

Page 7: ...A PLASTIC ENCLOSURE 3TANDOFFS ATTACH TO HEATER MOUNTING BRACKET PN 53933 A B C D E A B C D E 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 TORQUE RANGE FOR TB1 27 30 IN LBS HOT BLACK NEUTRAL WHITE HOT RED K6 K1...

Page 8: ...SING OR ON THE MAIN BOARD s ONNECT WIRE ON THE 8 0 TO ON THE MAIN BOARD s ONNECT 7 ON THE 8 0 TO 2ED 6 OR 7HITE 6 ON THE MAIN BOARD AN ALSO BE USED WITH A 03 CABLE 0 TO CONTROL TWO SPEED 0UMPS PN 5513...

Page 9: ...Y Celsius 1 DIP Switch Sets default for user preferences only applies when persistent memory is reset A12 On during power up Timeouts 1 F 2 3 4 5 6 1 6 10 20 30 40 50 60 minutes F 15 minutes Pump 1 Lo...

Page 10: ...X P332 board 3 DIP Switch Pump 4 Speeds 0 Y 0 Disabled Y On Off on pin 2 of X P332 board 3 DIP Switch Blower Speeds 0 1 2 3 0 Disabled 1 On Off on main board 2 2 speeds on X TB board 3 3 speeds on X T...

Page 11: ...y is reset A12 On during power up Cleanup Cycles as User Preference n Y n Only in Configuration Settings Y Over rideable by User via User Preferences Ozone Operation A F A Operates with Heater Pump Pu...

Page 12: ...8 7 Aux Button 4 Bank B 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 1 6 Assigns Pump Number Pump 1 Pump 2 etc b Blower g Spa Light F Fiber Optic wheel light E EitherLight o Option 1 t Mister 1 d M...

Page 13: ...0 C Sets default for user preferences only applies when persistent memory is reset A12 On during power up Uppermost Set Temperature 5 6 7 8 9 0 1 2 3 4 E F n 5 95 F 35 0 C 6 96 F 35 5 C 7 97 F 36 0 C...

Page 14: ...F g H J L n o P r Filter 1 Duration Set 2 0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r Filter 2 Start Hour Set 2 0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r Filter 2 Duration Set 2 0 1 2 3 4 5...

Page 15: ...s 1 5 1 5 minutes t 10 minutes Blower Purge Duration 5 1 2 3 4 6 t F 5 5 seconds 1 10 seconds 2 20 seconds 3 30 seconds 4 45 seconds 6 60 seconds 1 minute t 2 minutes F 5 minutes Mister Purge Duration...

Page 16: ...2 3 6 7 8 DOLPHIN REMOTE ROUND REMOTE Remote Button 1 Set B 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 Remote Button 2 Set B 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 Remote Button 3 Set B...

Page 17: ...2 3 4 8 7 6 5 Time Warm Warm Mode e Cool ML90x Custom Buttons Enable n Y n Disabled Y Enabled 1 DIP Switch ML75x MX75x Custom Button 1 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 ML75x MX75x Custo...

Page 18: ...ch ML55x Custom Button 1 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 ML55x Custom Button 2 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 ML55x Custom Button 3 1 2 3 4 5 6 b g F E o t d P n A U r...

Page 19: ...ir 7 Option 5 ML400 1 2 3 ML200 3 2 1 ML260 3 2 1 ML240 3 2 1 Temp Temp Temp Temp Temp Temp Temp Temp ML40x ML2xx Custom Buttons Enable n Y n Disabled Y Enabled 1 DIP Switch Special Amperage Rule 1 2...

Page 20: ...uit board is factory configured to deliver a preset voltage 120V or 240V to the on board ozone connector J29 or J17 See the ratings table on the wiring diagram attached to the cover of the enclosure f...

Page 21: ...erminal J70 or J71 ML700 PN ______ with Overlay PN ______ s Connects to Main Panel terminal J70 or J71 Jets 3 Option Jets 1 Option Invert Blower Fiber Option Jets 1 Option Invert Blower Fiber T IME C...

Reviews: