2.2 Receiving and inspection
When you receive your DSM, there are several things you should do immediately:
1. Check the condition of the packaging and report any damage immediately to the carrier
that delivered your DSM.
2. Remove the DSM from the shipping container and remove all packing material. The container
and packing materials may be retained for future shipment.
3. Verify that the catalog number of the DSM you received is the same as the catalog
number listed on your purchase order. The catalog/part number is described in the next
section.
4. Inspect the DSM for external damage during shipment and report any damage to the
carrier that delivered it.
5. If the DSM is to be stored for several weeks before use, be sure that it is stored in a
location that conforms to the storage humidity and temperature specifications shown in
section 3.1.1.
2.2.1 Identifying the catalog number
Different models of DSM are available. As a reminder of which product has been installed, it is
a good idea to write the catalog number in the space provided below.
DSM catalog number:
DSMS______-______-__
Installed in:
________________________
Date:
______
A description of a catalog number is shown here, using the example
DSMS34F-3B-M
:
Meaning
Alternatives
DSMS
DSM S-series family
-
34
NEMA 34 frame size
17
=NEMA 17;
23
=NEMA 23
F
Flying lead connections
P
=7-pin terminal block
3
Large stack size
1
=Small stack size;
2
=Medium stack size
B
Supply voltage 12 - 75 VDC
(DSMS23 / DSMS34 only)
A
=Supply voltage 12 - 48 VDC
M
(Optional) Manual control knob
-