2-2 Introduction
MN1902
2.2 Receiving and inspection
When you receive your FlexDrive
II
, there are several things you should do immediately:
1. Check the condition of the shipping container and report any damage immediately to the
carrier that delivered your FlexDrive
II
.
2. Remove the FlexDrive
II
from the shipping container and remove all packing material. The
container and packing materials may be retained for future shipment.
3. Verify that the catalog number of the FlexDrive
II
you received is the same as the catalog
number listed on your purchase order. The catalog number is described in the next section.
4. Inspect the FlexDrive
II
for external damage during shipment and report any damage to the
carrier that delivered your FlexDrive
II
.
5. If FlexDrive
II
is to be stored for several weeks before use, be sure that it is stored in a location
that conforms to the storage humidity and temperature specifications shown in section 7.1.18.
2.2.1 Identifying the catalog number
The FlexDrive
II
is available with different current ratings and package sizes. The catalog
number is marked on the front of the unit, just below the Baldor logo. It is a good idea to look
for the catalog number (sometimes shown as ID/No: ) and write it in the space provided here:
Catalog number:
F_H
______________-________
Installed at:
________________________
Date:
______
A description of a catalog number is shown here, using the example
FDH1A05TB-RC23
:
Meaning
Alternatives
FDH
FlexDrive
II
family
FPH
=Flex+Drive
II
1
Requires an AC supply voltage of 115 Volts, 1
Φ
2
=230V (1
Φ
or 3
Φ
);
4
=230V-460V (3
Φ
)
A05
Continuous current rating of 5.0A
A02
=2.5A;
A07
=7.5A;
A15
=15A;
A20
=20A;
A27
=27.5A
T
Built in AC power supply
-
B
Dynamic Brake with a built in transistor and
resistor (available on 2.5A and 5A models only)
R
= Requires external braking
resistor
R
Feedback option is a resolver
E
=Encoder;
D
=EnDat (absolute encoder)
C
Option fitted: 1 CAN channel
B
=CAN & Auxiliary I/O
(Flex+Drive
II
only);
D
=DeviceNet;
P
=Profibus DP;
N
=No options specified
2
Serial port type is combined RS232 / RS485
-
3
Customer’s own 24VDC supply is required to
power the internal FlexDrive
II
logic
0
= Internally generated 24VDC
supply*
*
An external 24VDC supply will always be required to operate the enable input, digital inputs
and digital outputs on connector X3 . See sections 4.3.1 to 4.3.5.
Summary of Contents for Flex+DriveII
Page 1: ...FlexDriveII Flex DriveII Servo Controls SERVO DRIVE Installation Manual 10 02 MN1902...
Page 2: ......
Page 14: ...2 4 Introduction MN1902...
Page 68: ...4 20 Input Output MN1902...
Page 80: ...5 12 Operation MN1902...
Page 98: ...7 12 Specifications MN1902...
Page 106: ...A 8 Accessories MN1902...
Page 122: ...Index MN1902...
Page 124: ...Comments MN1902 Thank you for taking the time to help us...
Page 125: ......