4-18 Input / Output
MN1902
4.5 Connection summary - minimum system wiring
As a guide, Figure 37 shows an example of the typical minimum wiring required to allow the
FlexDrive
II
to control a motor.
COM
Host PC
AC power
Motor
power
U V W
Serial communication
To regen
resistor
(Dynamic
brake)**
Customer
supplied
24V**
Motor
Drive
enable
switch
+24V
+24V 0V
** Model shown: FDH2A07TR-RN23:
This model requires an external regeneration resistor and customer supplied 24V supply - see sections 3.6 and 3.4.7.
Some models contain an internal 24V supply and/or an internal regeneration resistor.
Command input may be differential (shown) or single ended. See section 4.2.1.
Motor represents a typical Baldor BSM motor. Linear motors may also be controlled by FlexDrive
II
.
Shield earth/ground clamps are not supplied.
0V
Filter
L
N
PE
L
N
E
Star
point
If the filter has no output
earth/ground terminal, earth
wire may be connected
directly to the star point.
AC
power
in
L
N
E
Shield earth/ground clamp
attached to enclosure backplane
Command
input
Figure 37 - Example minimum system wiring
Summary of Contents for Flex+DriveII
Page 1: ...FlexDriveII Flex DriveII Servo Controls SERVO DRIVE Installation Manual 10 02 MN1902...
Page 2: ......
Page 14: ...2 4 Introduction MN1902...
Page 68: ...4 20 Input Output MN1902...
Page 80: ...5 12 Operation MN1902...
Page 98: ...7 12 Specifications MN1902...
Page 106: ...A 8 Accessories MN1902...
Page 122: ...Index MN1902...
Page 124: ...Comments MN1902 Thank you for taking the time to help us...
Page 125: ......