www.baldormotion.com
8-6 Specifications
MN1901
230VAC three-phase models
(Catalog number MDH2A15...)
Unit
15A
Switching threshold
VDC
on: 376, off: 365
Nominal power
(10% power cycle)
kW
1.0
Peak power
(10% power cycle)
kW
15
Maximum regeneration
switching current
A
RMS
40
Maximum load inductance
μ
H
100
230-460VAC three-phase models
(Catalog number MDH4...)
Unit 2.5A
5A
7.5A
15A
20A
27.5A
Switching threshold
V
in
=400VAC
V
in
=460VAC
VDC
on / off: 750
on / off: 750
Nominal power
(10% power cycle)
kW
0.94
2.9
Peak power
(10% power cycle)
kW
9.4
29
Maximum regeneration
switching current
A
RMS
15
40
80
Maximum load inductance
μ
H
100
*Note:
2.5A models (
MDH4
A02
xx-xxxx
) contain an internal 200
Ω
, 300W resistor.
5A models (
MDH4
A05
xx-xxxx
) contain an internal 200
Ω
, 300W resistor.
8.1.6 Analog input (X3)
All models
Unit
All models
Type
Differential
Common mode voltage range
VDC
±10
Common mode rejection
dB
40
Input impedance
k
Ω
>5
Input ADC resolution
bits
14
(includes sign bit)
Equivalent resolution
mV
±1.2
Sampling interval
Software (Mint programs)
High speed demand reference signal
μ
s
500
125