5-6 Software Setup
Standard Series H Area Register Mapping
Continued
Register
Address
T#
Read/Write
Description
48100
6
Read/Write
Hz Speed Ref
48101
7
Read/Write
Speed Ref (RPM)
48102
8
Read/Write
Speed Ref (High resolution –
1/256 RPM) (low order)
48103
8
Read/Write
Speed Ref (High resolution –
1/256 RPM) (high order)
48104
9
Read/Write
Torque Ref (
±
15 bits = programmed current limit)
48105
10
Read/Write
Process Ref (
±
14 bits = full scale)
48106
11
Read/Write
Process Feedback (
±
14 bits = full scale)
48107
12
Read/Write
Position Ref (scaling=quadrature
counts) (low order)
48108
12
Read/Write
Position Ref (scaling=quadrature
counts) (high order)
48109
13
Read/Write
Position Speed (RPM)
48110
14
Read/Write
Position Feed Fwd
48111
15
Read/Write
Position (scaling=quadrature counts) (low order)
48112
15
Read/Write
Position (scaling=quadrature counts) (high order)
48113
16
Read/Write
Home Offset (low order)
48114
16
Read/Write
Home Offset (high order)
48120
52
Write Only
Calc Presets (1=execute preset calculation)
48121
53
Read/Write
Auto Tune Mode (0=no test/cancel test)
48122
54
Read Only
Auto Tune Data
48123
55
Read Only
Auto Tune Status (0=failed, 1=pass, 2=running)
Summary of Contents for Modbus Plus