3-2 Basic Installation
MN1903
3.2 Location requirements
It is essential that you read and understand this section before beginning the
installation
.
CAUTION
: To prevent equipment damage, be certain that input and output signals
are powered and referenced correctly.
CAUTION
: To ensure reliable performance of this equipment be certain that all
signals to/from the NextMove PCI are shielded correctly.
CAUTION
: Avoid locating the NextMove PCI or host PC immediately above or beside
heat generating equipment, or directly below water steam pipes.
CAUTION
: Avoid locating the NextMove PCI or host PC in the vicinity of corrosive
substances or vapors, metal particles and dust.
The safe operation of this equipment depends upon its use in the appropriate environment.
The following points must be considered:
H
The NextMove PCI must be installed in an enclosed cabinet located so that it can only be
accessed by service personnel using tools.
H
The maximum suggested operating altitude is 6560ft (2000m).
H
The NextMove PCI must be installed in an ambient temperature of 32°F to 104°F
(0°C to 40°C).
H
The NextMove PCI must be installed in relative humidity levels of less than 80% for
temperatures up to 87°F (31°C) decreasing linearly to 50% relative humidity at 104°F
(40°C) (non-condensing).
H
The NextMove PCI must be installed where the pollution degree according to IEC664 shall
not exceed 2.
H
Power is supplied to the card from the host PC power supply bus.
H
The atmosphere shall not contain flammable gases or vapors.
H
There shall not be abnormal levels of nuclear radiation or X-rays.
Summary of Contents for NextMove PCI
Page 1: ...NextMove PCI Motion Controller MOTION CONTROL Installation Manual 3 02 MN1903...
Page 2: ......
Page 6: ...iv Contents MN1903...
Page 16: ...3 4 Basic Installation MN1903...
Page 42: ...4 26 Input Output MN1903...
Page 57: ...Operation 5 15 MN1903 Figure 11 The NextMove PCI servo loop...
Page 74: ...5 32 Operation MN1903...
Page 90: ...A 8 Accessories MN1903...
Page 91: ......