Input / Output 4-11
MN1903
The inputs are conditioned using low pass RC filters and Schmitt trigger buffers. If an input is
configured as edge triggered, the triggering pulse must have a duration of at least 1ms (one
software scan) to guarantee acceptance by MintMT. Voltages below 2V are considered as 0V.
The use of shielded cable for inputs is recommended.
Active high
: The digital inputs will be active when a voltage of +24VDC (±20%) is applied to
them and will sink a maximum of 8mA each.
Active low
: The digital inputs will be active when grounded (<2V) and will source a maximum
of 8mA each.
Note:
Sustained input voltages above 28V will damage the inputs.
4.4.2 Digital inputs - X2
Location
Breakout module, connector X2
Pin Name
MintMT
keyword
/
description
Common
1 Shield
Shield connection
2 DIN4
INX.4
3 DIN5
INX.5
Common1
4 DIN6
INX.6
Common1
5 DIN7
INX.7
6 DIN8
INX.8
7 DIN9
INX.9
Common2
8 DIN10
INX.10
Common2
9 DIN11
INX.11
10 Shield
Shield connection
11 Common1
Common connection
12 Common2
Common connection
Description
Eight general purpose optically isolated AC digital inputs.
The inputs are electrically identical to inputs DIN12 to DIN19 described in section 4.4.1.
1
12
Summary of Contents for NextMove PCI
Page 1: ...NextMove PCI Motion Controller MOTION CONTROL Installation Manual 3 02 MN1903...
Page 2: ......
Page 6: ...iv Contents MN1903...
Page 16: ...3 4 Basic Installation MN1903...
Page 42: ...4 26 Input Output MN1903...
Page 57: ...Operation 5 15 MN1903 Figure 11 The NextMove PCI servo loop...
Page 74: ...5 32 Operation MN1903...
Page 90: ...A 8 Accessories MN1903...
Page 91: ......