Input / Output 4-13
MN1903
4.4.4 Digital outputs - X4
Location
Breakout module, connector X4
Pin Name
MintMT
keyword
/ description
1 Shield
Shield connection
2 DOUT6
OUTX.6
3 DOUT7
OUTX.7
4 DOUT8
OUTX.8
5 DOUT9
OUTX.9
6 DOUT10
OUTX.10
7 DOUT11
OUTX.11
8 -
(NC
)
9 -
(NC)
10 Shield
Shield connection
11 USR V+
Customer power supply
12 CGND
Customer power supply ground
Description
Six general purpose optically isolated digital outputs.
Output current: 50mA maximum each output
Update frequency: Immediate
Each optically isolated output is designed to source current from the customer supplied
12-24V supply (USR V+) as shown in Figure 5. The use of shielded cable is recommended.
The CGND must be connected to the host PC’s GND. See section 4.5.3 for details about
connecting the USR V+ supply.
OUTX.6
USR V+
NextMove PCI
DOUT6
Output
module
CGND
Output
load
Breakout
module
2
11
X4
100
pin
cable
12
Figure 5 - Digital output circuit with standard ‘PNP’ current sourcing module - DOUT6 shown