background image

3-10 Maintenance & Troubleshooting

MN605

Accessories

The following list shows some accessories available through Baldor’s Mod Express or available on

custom manufactured motors. Contact your Baldor supplier for information on each additional accessory

or those listed below.

Bearing RTD

RTD (Resistance Temperature Detector) devices are used to measure or monitor the temperature of

the motor bearing during operation.

Bearing Thermocouple

s

Used to measure or monitor bearing temperatures.

Bearing Thermostat

Temperature device that activates when bearing temperatures are excessive. Used with an external

circuit to warn of excessive bearing temperature or to shut down a motor.

Blowers with Filters:

Available to increase the constant torque speed range of DPFG motors. This increases the

continuous operating torque range at low speeds.

Brush Wear Indicator:

Provides a warning when the brushes have worn down to the level where they need to be replaced

(before damage to the commutator).

Condensation Drains & Breathers:

Stainless steel drains and separate breathers are available.

Conduit Boxes

Optional conduit boxes are available in various sizes to accommodate accessory devices.

Cord & Plug Assembly

Adds a line cord and plug for portable applications.

Drip Covers

Designed for use when motor is mounted in a vertical position.  Contact your Baldor distributor to

confirm that the motor is designed for vertical mounting.

Fan Cover & Lint Screen

To prevent build-up of debris on the cooling fan.

Nameplate

Additional stainless steel nameplates are available.

Roller Bearings

Recommended for belt drive applications with a speed of 1800 RPM or less.

Rotation Arrow Labels

Rotation arrows are supplied on motors designed to operate in one direction only.  Additional rotation

arrows are available.

Slide Bases:

Allows easy belt adjustment while maintaining correct pulley and belt alignment.

Space Heater

 

Added to prevent condensation of moisture within the motor enclosure during periods of shut down or

storage.

Stainless Hardware

Stainless steel hardware is available.  Standard hardware is corrosion resistant zinc plated steel.

Tachometers:

DC, AC and digital outputs are available. These can be mounted to our motors or shipped separately.

Tachs help the SCR control achieve more precise speed regulation than by armature feedback alone.

Transparent Brush Inspection:

For easy brush inspection and commutation monitoring without disassembly of the motor.

Winding RTD

RTD (Resistance Temperature Detector) devices are used to measure or monitor the temperature of

the motor winding during operation.

Winding Thermocouples

Used to measure or monitor winding temperatures.

Winding Thermostat

Temperature device that activates when winding temperatures are excessive. Used with an external

circuit to warn of excessive winding temperature or to shut down a motor.

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for Reliance CDX7150

Page 1: ...ss underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos...

Page 2: ...Integral Horsepower DC Motor Installation Operating Manual 2 09 MN605 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 3: ...Any trademarks used in this manual are the property of their respective owners Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 4: ...2 Conduit Box 2 2 Power 2 2 Motor Connections 2 2 Thermostats 2 3 Initial Start Up 2 5 Coupled Start Up 2 5 Section 3 Maintenance Troubleshooting 3 1 General Inspection 3 1 Lubrication Bearings 3 2 T...

Page 5: ...ers Filters 3 8 Troubleshooting 3 8 Armature Overheating 3 8 Field Coil Overheating 3 9 Excessive Load 3 9 Jogging and Repeated Starts 3 9 Heating 3 9 Thermostat 3 9 Troubleshooting Chart 3 10 Accesso...

Page 6: ...nel should attempt the installation operation and maintenance of this equipment WARNING Disconnect all electrical power from the motor windings and accessory devices before disassembly of the motor El...

Page 7: ...are used for lifting a motor be sure they are securely tightened The lifting direction should not exceed a 20 angle from the shank of the eye bolt or lifting lug Excessive lifting angles can cause dam...

Page 8: ...ransportation Improper motor storage will result in seriously reduced reliability and failure An electric motor that does not experience regular usage while being exposed to normally humid atmospheric...

Page 9: ...on brushes should be lifted and held in place in the holders above the commutator by the brush holder fingers The commutator should be wrapped with a suitable material such as cardboard paper as a mec...

Page 10: ...o minimize vibration and maintain alignment between the motor and shaft load Failure to provide a proper mounting surface may cause vibration misalignment and bearing damage Foundation caps and sole p...

Page 11: ...ctural or decorative parts of the driven equipment 2 Providing covers for the rotating parts Covers should be sufficiently rigid to maintain adequate guarding during normal service Power Connection Mo...

Page 12: ...B C C 5V COMMON Electrically Isolated Encoder Color Codes for Optional Baldor Encoder Cable Standard Receptacle MS3112W12 10P Standard Plug MS3116J12 10S Thermostats The thermostat is a pilot circuit...

Page 13: ...drawing or rotation arrow shown on the blower housing Refer to Figure 2 1 Figure 2 1 View from Air Inlet Motor is on Opposite Side Air Inlet Housing Impeller Blades Airflow Table 2 4 Electrical Data F...

Page 14: ...otor may reach destructive high speeds If the direction of rotation needs to be corrected disconnect the input power supply and interchange the appropriate leads Refer to the motor connection diagrams...

Page 15: ...2 6 Installation Operation MN605 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 16: ...sive vibration will damage the motor bearings brushes and commutator 5 Listen for unusual noises especially in the area of the bearings Also rubbing or rumbling noises could be signs of internal damag...

Page 17: ...to 210 incl 132 5500 Hrs 12000 Hrs 18000 Hrs 22000 Hrs Over 210 to 280 incl 180 3600 Hrs 9500 Hrs 15000 Hrs 18000 Hrs Over 280 to 360 incl 225 2200 Hrs 7400 Hrs 12000 Hrs 15000 Hrs Over 360 to 500 in...

Page 18: ...Remove grease outlet plug 3 If motor is stopped add the recommended amount of grease If motor is to be greased while running a slightly greater quantity of grease will have to be added Add grease slow...

Page 19: ...ositioning of the brush box During periodic inspections check that electrical connections are tight and properly insulated Brush Springs Brush springs should be inspected for proper tension during bru...

Page 20: ...ofit motors Contact your local Baldor District Office or an Authorized Baldor Service Center for technical assistance Do not change brush grades or the number of brushes per pole Doing so may void the...

Page 21: ...he commutator surface With increased loads and increased spring pressure this condition can be avoided Grooving May result from an overly abrasive brush grade The more common cause is poor electrical...

Page 22: ...ature must be removed from the motor and the commutator machined by a qualified repair shop Rapid Commutator Wear Light electrical loads and contamination are the usual causes of rapid commutator wear...

Page 23: ...e an averaging type ammeter if the motor s power is coming from a rectifier or SCR control Jogging and Repeated Starts Repeated starts or jogs of motors may reduce the life of the brushes and winding...

Page 24: ...nded winding Perform dielectric test and repair as required Improper connections Inspect all electrical connections for proper termination clearance mechanical strength and electrical continuity Refer...

Page 25: ...hat the motor is designed for vertical mounting Fan Cover Lint Screen To prevent build up of debris on the cooling fan Nameplate Additional stainless steel nameplates are available Roller Bearings Rec...

Page 26: ...d AC 3 Drive generator at rated RPM 4 Measure the voltage across A1 and A2 Voltage should be 150 to 200 of F1 to F4 voltage When A1 to A2 voltage level reaches this level approximately 30 seconds care...

Page 27: ...3 12 Maintenance Troubleshooting MN605 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 28: ...ries Motor CW Rotation Facing Commutator End Armature A1 A2 S2 S1 Compound or Stabilized Shunt Motor CCW Rotation Facing Commutator End High Voltage Field Connection Shunt Field F1 F2 F3 F4 A1 A2 S2 S...

Page 29: ...d Interpole Series Field Comm Field Shunt Field Shunt Motor CW Rotation Facing Commutator End High Voltage Field Connection Armature Shunt Field Interpole Field Reversing Shunt Motor CCW Rotation Faci...

Page 30: ...Baldor District Offices Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 31: ...reserved Printed in USA 2 09 BALDOR ELECTRIC COMPANY World Headquarters P O Box 2400 Fort Smith AR 72901 2400 479 646 4711 Fax 479 648 5792 www baldor com Artisan Technology Group Quality Instrumentat...

Page 32: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: