12-8 Monitor and RTC Description
MN766
Table 12-2 Actions (P3601 & 3602)
ID
ACTION
DESCRIPTION
0
None
No action assigned. Default setting.
1
Digital Output 1 On
Digital output 1 is turned on. P1501 set to RTC.
2
Digital Output 1 Off
Digital output 1 is turned off. P1501set to RTC
3
Digital Output 2 On
Digital output 2 is turned on. P1502 set to RTC
4
Digital Output 2 Off
Digital output 2 is turned off. P1502 set to RTC
5
Relay Output 1 On
Relay output 1 is turned on. P1503 set to RTC
6
Relay Output 1 Off
Relay output 1 is turned off. P1503 set to RTC
7
Relay Output 2 On
Relay output 2 is turned on. P1504 set to RTC
8
Relay Output 2 Off
Relay output 2 is turned off. P1504 set to RTC
9
Increment P107
Increments the RTC counter parameter
10
Decrement P107
Decrements the RTC counter parameter
11
Reset P107
Resets the RTC counter parameter
12
Digital Output 1 On with Inc
Performs digital I/O with P107 increment
13
Digital Output 1 Off with Inc
Performs digital I/O with P107 increment
14
Digital Output 1 On with Dec
Performs digital I/O with P107 decrement
15
Digital Output 1 Off with Dec
Performs digital I/O with P107 decrement
16
Digital Output 1 On with Reset
Performs digital I/O with P107 reset
17
Digital Output 1 Off with Reset
Performs digital I/O with P107 reset
18
Relay Output 1 On with Inc
Performs digital I/O with P107 increment
19
Relay Output 1 Off with Inc
Performs digital IO with P107 increment
20
Relay Output 1 On with Dec
Performs digital IO with P107 decrement
21
Relay Output 1 Off with Dec
Performs digital IO with P107 decrement
22
Relay Output 1 On with Reset
Performs digital IO with P107 reset
23
Relay Output 1 Off with Reset
Performs digital IO with P107 reset
Level 1, Output Setup Block parameters P1501-P1504 select the digital/relay output functions. P107 is the RTC counter
parameter.
Message Module (P3603 - 3604)
Message Module parameters P3603 - 3604 set the messages to be scheduled. Message selections are shown in Table 12-3.
Table 12-3 RTC Message 1&2 Parameters (P3603 & P3604)
ID
ACTION
DESCRIPTION
0
None (default)
No message active
1
Clean Filter(s)
Time to do periodic cleaning of fi lter(s)
2
Change Filter(s)
Time to change out the fi lter(s)
3
Apply Oil/Lubricate
Apply oil and/or lubricant necessary areas of the system
4
Service Motor
Check motor cables, resolver, clean motor etc.
5
Service Drive
Check drive cables, clean panels and keypad display etc.
6
Service Coolant System
Check coolant pressures/levels, check for leaks, top off as needed
7
Service Heating System
Check for gas leaks, clean fi lters, blowers and connections
8
RTC Alarm
Generic real-time clock alarm
Summary of Contents for VS1SD
Page 1: ...05 13 Installation Operating Manual MN766 VS1SD AC Servo Control...
Page 12: ...2 2 General Information MN766...
Page 16: ...3 4 Installing the Drive MN766...
Page 108: ...7 34 Parameter Descriptions MN766...
Page 114: ...8 6 Customizing Your Application MN766...
Page 128: ...9 14 Troubleshooting MN766...
Page 154: ...12 12 Monitor and RTC Description MN766...