4-12 Power Wiring
MN766
4.13 Brushless Servo Motor Identifi cation
Figure 4-12
A = Resolver
D = Absolute Encoder
E = Encoder w/Commutation (1000ppr)
F = Encoder w/Commutation (2500ppr)
H = Hall effect only
T = Tach/Hall effect
Y = Resolver mounting only
Blank = No Option
M = No Keyway
N = DIN 42955-R
O = DIN 42955-R & No Keyway
P = Optional Motor Connector on BSM 90/100
(Note: This option available only if current is 20 amps or less).
Z1 = Blower 115 VAC (not available on all motors)
Z2 = Blower 230 VAC (not available on all motors)
Z3 = Blower 24VDC
Accessory Options
Feedback Options
IEC NEMA
50 5N
63 6N
80 8N
90 9N
100
C
N
1
2
3
4
50
75
etc.
SS = Stainless
Steel
Motor (no shaft seal)
Motor & Brake
Motor with shaft oil seal
Motor with brake & shaft oil seal
A
B
C
D
Description
Standard (Metric)
Threaded Style
I
J
K
L
Optional (inch)
Quick Connect
E
F
G
H
Cables (5)
Connections
M
N
O
P
Flying
Leads (5)
R
S
T
U
Rotatable
Metric Threaded (9)
Notes: 1)
2) Standard BSM90/100 Series includes feedback device, one threaded connector (metric style) for feedback, termination of motor lead
wires on terminal block, IEC square mounting flange.
3) Standard BSM motors do not have shaft seal. Motors will meet IP65 if shaft oil seal is added.
4) Standard BSM50 Series has as standard no-keyway.
5) Standard cables and flying leads are 1 meter long.
6) SSBSM motors available with IEC mounting and include a shaft oil seal as standard.
7)
BSM motors are IP60. Motors that meet IP65 include shaft oil seal.
8)
SSBSM motors are IP67.
9)
Rotatable connectors are not available for BSM50 series.
10) Contact Baldor for special option availabliity.
Motor Options
Frame
Motor
Size
Winding
Code
Series
Standard BSM50/63/80 Series includes feedback device, two threaded connectors (metric style) for feedback and motor terminations,
IEC square mounting flange.
4.14 External Trip Input
Terminal J2-16 is available for connection to a normally closed contact. The contact should be a dry contact type with no
power available from the contact. When the contact opens (activated), the control will automatically shut down and give an
External Trip fault.
Summary of Contents for VS1SD
Page 1: ...05 13 Installation Operating Manual MN766 VS1SD AC Servo Control...
Page 12: ...2 2 General Information MN766...
Page 16: ...3 4 Installing the Drive MN766...
Page 108: ...7 34 Parameter Descriptions MN766...
Page 114: ...8 6 Customizing Your Application MN766...
Page 128: ...9 14 Troubleshooting MN766...