Using the Keypad 6-13
MN766
6.9 Diagnostics
From the Menu display screen, select Diagnostics and press enter. These are read only values with the exception of the real
time clock settings.
See Chapter 9 for a more detailed description.
Action
Description
Display
Comments
Press Menu.
Displays top level menu options.
STATUS
BASIC PARAMS
ADVANCED PROG
EVENT LOG
DIAGNOSTICS
STATUS
BACK
Press
or
to move cursor over
the “DIAGNOSTICS” selection.
Press
to display next
group.
Displays active operating mode
settings.
STATUS
0.00r
MAIN
OPERATING MODE
Keypad
Speed
AC Servo
DIAG
STOP
LOCAL
Press to display next
group.
Bit display of digital inputs,
outputs and the voltage present at
the internal 24V supply terminals.
STATUS
0.00r
MAIN
DIGITAL I/O
INPUTS
100000000
OUTPUTS
0001
USER 24V
24.9V
DIAG
STOP
LOCAL
Press
or
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
Press to display next
group.
Output
Frequency, % Feedforward
% Setpoint, % Feedback
STATUS
0.00r
MAIN
PROC CONTROL PID
0.00HZ 0.0FF
0.0SP 0.0FB
DIAG
STOP
LOCAL
Press
or
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
Note: This screen does not appear
unless P1401 is set to
Displays software version, hp,
volts and Amp/Volt ratings.
STATUS
0.00r
MAIN
SHH-1.21
RATED HP
3HP
RATED VOLTS
240.0V
RATED A/V
4.0A/V
DIAG
STOP
LOCAL
Press
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
Press
to display next
group.
STATUS
0.00r
MAIN
RATED CURRE
9.6A
RATED PK CU
16.8A
DIAG
STOP
LOCAL
Press
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
Press
to display next
group.
Displays:
Power Base ID number
EE Firmware version
FPGA Firmware version
STATUS
0.00r
MAIN
POWER BASE VERSION
ID
0x000A2003
EE VER
0x00000001
FPGA VER
0x00000A02
DIAG
STOP
LOCAL
Press
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
0x=Hexadecimal
0b=Binary
Press
to display next
group.
Displays real time clock values
(date and time) and total run time
since installation.
Press ENTER to set date and
time.
STATUS
0.00r
MAIN
REAL TIME CLOCK
Jul 4, 2006
22:07:35
RUN TIMER
474.1HR
DIAG
STOP
LOCAL
Press
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
or
or
or
or
Note: Example display shows that
the drive enable terminal
(J2-8) is on and that
Relay Out 2 is on.
SHH-1.21
Press Enter to view diagnostic
information.
Press
to display next
group.
Process Control.
Press F1 to go to STATUS screen.
Press F1 to go to STATUS screen.
Press F1 to go to STATUS screen.
Press F1 to go to STATUS screen.
Press F1 to go to STATUS screen.
Press F1 to go to STATUS screen.
Summary of Contents for VS1SD
Page 1: ...05 13 Installation Operating Manual MN766 VS1SD AC Servo Control...
Page 12: ...2 2 General Information MN766...
Page 16: ...3 4 Installing the Drive MN766...
Page 108: ...7 34 Parameter Descriptions MN766...
Page 114: ...8 6 Customizing Your Application MN766...
Page 128: ...9 14 Troubleshooting MN766...
Page 154: ...12 12 Monitor and RTC Description MN766...