6-16 Using the Keypad
MN766
6.11 Operating the Control from the Keypad
To activate the LOCAL Mode, fi rst press the “STOP” key (if enabled).
Note:
Pressing the keypad STOP key (if enabled) will automatically issue a motor stop command and change to LOCAL
mode. Selection of LOCAL Mode overrides any remote or serial control inputs except the External Trip input, Local
Enable Input or STOP input.
The control can operate the motor from the keypad in two ways.
1. JOG Command.
2. Speed adjustment with Keypad entered values and/or Keypad Up/Down arrow keys.
Note:
If the level 1, input block operating mode parameter is set to Keypad, then no other means of operation is permitted
other than from the keypad.
6.11.1 Accessing the Keypad JOG Command
Action
Description
Display
Comments
Status Display
STATUS
STOP
LOCAL
DIAG
0.00r
MAIN
0.0V
0RPM
0.0A
0.0HZ
Press JOG key
Next, press and hold
the FWD or REV key
The JOG LED will light indicating
the JOG mode is active. Holding
the FWD or REV key starts JOG
operation.
Releasing FWD or REV key will
terminate motor rotation.
STATUS
FWD
LOCAL
DIAG
210r
MAIN
10.1V
210RPM
1.3A
7.0HZ
To change Jog Speed, Edit
Level 1 parameter P1201 (Jog
Speed).
Press STOP key twice to
terminate JOG mode.
6.11.2 Speed Adjustment using Local Speed Reference
Action
Description
Display
Comments
At the Status Display,
press ENTER key to
access Local Speed
Reference.
EDIT
LOCAL REFs
MAX
F0201
RESET
LOC SPEED REF
000000 RPM
EDIT
DIAG
F0201
BACK
LOC SPEED REF
000000 RPM
Press
to move cursor.
Press
to increase or
decrease value at cursor.
Press ENTER when finished and
save the new value.
EDIT
DIAG
C0201
BACK
LOC SPEED REF
000300 RPM
Press
to move cursor.
Press
to increase or
decrease value at cursor.
Press ENTER when finished and
save the new value.
Press FWD or REV key.
The control will turn the motor
shaft at the local speed ref speed.
STATUS
FWD
LOCAL
DIAG
300r
BACK
12.7V
300RPM
1.3A
10.0HZ
Press STOP key to terminate
local speed mode.
Press
to increase or
decrease motor speed during
rotation.
or
or
or
or
or
LOCAL REFs
LOCAL REFs
Summary of Contents for VS1SD
Page 1: ...05 13 Installation Operating Manual MN766 VS1SD AC Servo Control...
Page 12: ...2 2 General Information MN766...
Page 16: ...3 4 Installing the Drive MN766...
Page 108: ...7 34 Parameter Descriptions MN766...
Page 114: ...8 6 Customizing Your Application MN766...
Page 128: ...9 14 Troubleshooting MN766...
Page 154: ...12 12 Monitor and RTC Description MN766...