7-14 Parameter Descriptions
MN766
Block Title
Parameter (Number)
Selection (Value)
Parameter Name and Description
COMMUNI-
CATION
(Continued)
DRIVE ADDRESS
(1704)
Preset Value: 1
Range: 1 - 247
Sets the drive address for communication via USB or Modbus-RTU.
OPT CARD RESET
(1705)
Preset Value: 0
Range: 0 - 3
Off (0)
No Action.
Slot 1 (1)
Reset Expansion Board in slot 1.
Slot 2 (2)
Reset Expansion Board in slot 2.
Slots 1 & 2 (3)
Resets both Expansion boards 1 & 2.
Sends a power up reset command to all expansion boards, slot 1 only, or
slot 2 only.
SECURITY DEFAULT
(1706)
Preset Value: 0
Range: 0 - 1
No (0)
No Action.
Yes (1)
Reset settings.
Restores factory settings to Browser User ID and Password.
BROWSER USER ID
(1707)(1708)
Preset Value: baldor
ASCII user ID for the Ethernet Web Browser Option Board if installed.
BROWSER PASSWORD
(1709)
(1710)
Preset Value: baldor
Password for the Ethernet Web Browser Option Board if installed.
1740-1791
See documentation provided with communications expansion board.
CUSTOM
MOTOR
ALIGNMENT CURRENT
(1821)
Preset Value: 50.0%
Range: 2.0 to 100.0%
Sets the amount of d-axis current, as a percent of Motor Rated Amps,
during alignment of PM motors.
ALIGNMENT TIME
(1822)
Preset Value: 5.0
Range: 1.0 to 60.0 seconds
Sets the amount of time used for alignment at motor startup.
Table 7-1 Level 1 Parameter Block Defi nitions Continued
Summary of Contents for VS1SD
Page 1: ...05 13 Installation Operating Manual MN766 VS1SD AC Servo Control...
Page 12: ...2 2 General Information MN766...
Page 16: ...3 4 Installing the Drive MN766...
Page 108: ...7 34 Parameter Descriptions MN766...
Page 114: ...8 6 Customizing Your Application MN766...
Page 128: ...9 14 Troubleshooting MN766...
Page 154: ...12 12 Monitor and RTC Description MN766...