BDM 400 Microphones
Operating Instructions
16
BDM400 Operation Manual issue 10
3.5 M
ODIFYING
C
ONFIGURATION
S
ETTINGS
1. Enter the Configuration Mode as described in Section 3.3.
2. Press the “Fault Accept” button to step through to the
required location within the Configuration Table.
3. The “Busy” LED flashes to indicate the location within the
table and the “Speak Now” LED flashes to indicate the
current setting.
4. To modify the value of the current setting press the “Speak”
button the required number of times e.g. if the 3rd value is
required press the “Speak” button three times.
The Buzzer will then sound and the “Fault” LED will
illuminate for one second to show the value has been
accepted.
After a short delay the “Speak Now” LED will flash the
revised number of times.
5. To move to the next position within the configuration table
press the “Fault Accept” button.
6. To exit from Configuration Mode disconnect the RJ45 cable.
7. When the RJ45 cable is reconnected the microphone will use
the new configuration details.
Note: Before the Microphone can be used the RS485 button allocation
data must be downloaded from the BVRD2M.
Press and hold the "FAULT ACCEPT" button for 2 seconds to load the
current button allocation data.
It is necessary to download this data after entering Configuration Mode.
N
OTE
:
If the Protocol is changed then the Mic Address MUST
BE RE-ENTERED or the Channel Setting may be incorrect.