www.balluff.com
3
english
BAV MA-NC-00025-01
Condition Monitoring Toolkit Base Unit
No. 951567-726 EN · 01.Vorserie · E21; Subject to changes. Replaces D21.
Connecting all components
1.
Connect all sensors to the CMTK Base Unit.
2.
Establish the power supply for the CMTK Base Unit.
Connect directly from a laptop/PC to the system via LAN?
►
Use LAN-Port 1 (laptop/PC must be set up as dhcp-
client).
Connect the CMTK to an existing network via LAN?
►
Use LAN-Port 2 (and the system fetches an IP address
from your dhcp-server).
Starting up the system
1.
Enter the address http://cmtk in the webbrowser
(Google Chrome, Firefox, MS-Edge) or 192.168.10.1
(when connected to LAN-Port 1) or the assigned
IP address (when connected to LAN-Port 2).
2.
Login with the username
admin
and the provided
password.
You will be prompted to change the password
the first time you use the software.
3.
Start the wizard with
S
tart
I
nItIalIzatIon
and run through
the wizard.
The e-mail settings can be skipped and also
set up later.
1
a)
1b)
2)
3)
⇒
The following screen appears:
Accessing the data visualization
►
Click on the blue tile to navigate to the dashboard with
the the data visualization.
Via the
Back
button in the upper left corner
(arrow to the left) you get back to the system
view with the tiles.
⇒
The CMTK is successfully set up.
The first data will now be shown on the dashboard. If
necessary, further settings can be made and the display
can be configured as required.
Quick Start