background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BIC 1B0-IT1A7-Q40KFU-SM4A4A 

BIC 2B0-IT1A7-Q40KFU-SM4A5A 

 

User's Guide 

 

 

Summary of Contents for BIC 1B0-IT1A7-Q40KFU-SM4A4A

Page 1: ...BIC 1B0 IT1A7 Q40KFU SM4A4A BIC 2B0 IT1A7 Q40KFU SM4A5A User s Guide...

Page 2: ...of the Connector Insert 8 Disassembling the Holder 8 5 Energy Transmission 9 5 1 Derating 9 Remote Current as a Function of Ambient Temperature 9 Output Current of the BIC in Space 10 5 2 Reducing the...

Page 3: ...owing typographical conventions are uses in this manual Enumerations Enumerations is shown in the form of bulleted lists Entry 1 Entry 2 1 3 Symbols Note This symbol indicates general notes Attention...

Page 4: ...y to the instructions provided in this User s Guide Obligations of the owner operator The device is a piece of equipment in accordance with EMC Class A Such equipment may generate RF noise The owner o...

Page 5: ...e met Based on the EU Council recommendation 1999 519 EC in accordance with EN 62311 2008 this distance is regarded as the basic limit value or reference value for the safety of persons in electromagn...

Page 6: ...mponent In this way the IO Link functionality of the IO Link port on the master is made available without contact on the remote Pin 2 in the system is transparent The BIC system can only be operated u...

Page 7: ...B0 IT1A7 Q40KFU SM4A5A 200 4 2 Installation in Metal Device damage due to induction effects Metallic objects in front of and on the coil cap cause the sensing surface to be heated The sensing surface...

Page 8: ...mm BIC 1B0 IT1A7 Q40KFU SM4A4A 5 5 BIC 2B0 IT1A7 Q40KFU SM4A5A 5 5 The system may be operated at a greater distance and or offset What is defining is the power transmitted by the system 4 4 Permitted...

Page 9: ...teps 1 through 6 described in the following After the connector insert is rotated step 7 subsequent reassembly is performed in reverse order Disassembling the Holder 1 Loosen the grub screw 2 Pull off...

Page 10: ...verely loaded that it collapses the status of the resulting over temperature is reported Note If the BIC system is operated with a correspondingly severe load the output voltage of the Remote collapse...

Page 11: ...2 Reducing the Output Power on the Base with a Decoupled Remote To protect people and the environment the base component automatically reduces power which is emitted in the form of electromagnetic fie...

Page 12: ...ate High active bidirectional from the IO Link port on the master to the IO Link device and the reverse For every status change the direction is redetermined from the side which first generates a High...

Page 13: ...turned on Red flashing Under voltage Over voltage Red static Over temperature Mechanical Data Housing material Black plastic PBTP Housing degree of protection IP 67 only in plugged in and screwed down...

Page 14: ...ment Power M12 4 pin connector Pin Signal 1 24 V 2 transparent pin 3 GND 0 V 4 C Q IO Link Note The digital I O signal on Pin 2 can only be sent when the BIC is in IO Link mode If the IO Link master i...

Page 15: ...Pin 2 low Mechanical Data Housing material Black plastic PBTP Housing degree of protection IP 67 only in plugged in and screwed down state Dimensions W x H x D in mm 40 x 40 x 60 8 Weight 150 g Elect...

Page 16: ...ent Power M12 5 pin socket Pin Signal 1 24 V 2 transparent pin 3 GND 0 V 4 C Q IO Link 5 NC Note The digital I O signal on Pin 2 can only be sent when the BIC is in IO Link mode If the IO Link master...

Page 17: ...ler BIC 1B0 IT1A7 Q40KFU SM4A4A Base BIC 2B0 IT1A7 Q40KFU SM4A5A Remote www balluff com 16 8 Appendix 8 1 Ordering Information Product name Order code BIC 1B0 IT1A7 Q40KFU SM4A4A BIC007F BIC 2B0 IT1A7...

Page 18: ...w balluff com Balluff GmbH Schurwaldstrasse 9 D 73765 Neuhausen a d F Germany Phone 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 939473 726 EN 04 129664 Edition C20 Replaces Edition A20 Subjec...