background image

 
Operating Manual 
Inductive Positioning System BIP AD0-B014-01-EP02

  

No. 872877 EN E16 

 

 

 

3

 

10V 

0V 

0mm 

14mm 

10V 

0V 

2,5mm 

10mm 

Minimum width 

>7mm 

Wiring diagram   

 

 

 

 

   
 

 

 

 

 

Programming 

 

 
The sensor is set at the factory to the maximum detection 
range of 14mm. It is, however, possible to program the 
respective start and end points of the measuring range as 
needed. The start and end points must be at least 7mm 
from one another in this case.  
 
In order to program the sensor, the target must be located 
within the detection range of the sensor. In this case, the 
green LED illuminates. 
 
If the target is located outside of the detection range of 
the sensor, the red LED illuminates and programming is 
not possible. 
 
If the target is located outside of the programmed 
measuring range but within the detection range of the 
sensor, the green LED flickers. 
 
If the programming process is not completed, the sensor 
returns to the previously programmed state or, as the 
case may be, the state of delivery after 2 minutes. 
 
If an error occurs during programming, the red LED 
flashes slowly. After 20s, the sensor returns to the 
previously programmed state or the state of delivery. 
 
To reset the sensor to the state of delivery, press the 
programming button for approximately 8s until the green 
LED stops flashing. In doing so, the target must be 
located within the detection range of the sensor. 
 
To change the measuring range, perform the following 
steps. 
  
1. Move the position encoder into the detection range of 
the sensor. The green LED then illuminates.  
2. Press the button until the green LED flashes. In doing 
so, pay attention to the cover foil. Use no sharp objects. 
3. The sensor is now in programming mode. 
4. Move the target to the desired start point.  
5. Briefly press the programming button (< 1s). The red 
LED flashes rapidly. 
6. Move the target to the desired end point. The distance 
to the start point must be higher than 7mm. This is then 
indicated by the rapidly flashing green LED. 
7. Briefly press the programming button (< 1s). The green 
LED illuminates.  
8. The start and end points have been saved. The sensor 
is again in working mode. 
 
 
 
 

Characteristics 

 

 
Standard characteristic (typical slope): 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Reduced measuring range and falling characteristic 
curve: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for BIP AD0-B014-01-EP02

Page 1: ...rhalb des eingelernten Messbereiches und gibt diese als Spannungssignal im Bereich 0 10V aus Die rote LED signalisiert dabei das Verlassen des Messbereiches Die gr ne LED leuchtet wenn sich der Positi...

Page 2: ...ssung des Messsignals durch das Einbaumaterial zu minimieren siehe Einbauskizze 1 2 Wird neben dem Positionsgeber noch ein weiteres Metallteil vom Sensor erkannt f hrt dies zu ung ltigen Messsignalen...

Page 3: ...auftreten blinkt die rote LED langsam Nach 20s kehrt der Sensor in den zuvor programmierten bzw in den Auslieferungs zustand zur ck Um den Sensor in den Auslieferungszustand zur ck zu versetzen dr cke...

Page 4: ...0 mA Kurzschlussschutz ja Vertauschungsm gl gesch tzt ja Verpolungssicher ja Mechanische Daten Werkstoff Geh use PA Anzugsdrehmoment 0 5 Nm Werkstoff aktive Fl che PA Anschlussart Kabel Werkstoff Kabe...

Page 5: ...in the taught measuring range and outputs this position as a current signal in the range 0 10V Here the red LED indicates that the value is outside of the measuring range The green LED illuminates if...

Page 6: ...the measurement signal by the installation material see installation diagrams 1 2 If in addition to the position encoder another metal part is detected by the sensor invalid measurement signals result...

Page 7: ...curs during programming the red LED flashes slowly After 20s the sensor returns to the previously programmed state or the state of delivery To reset the sensor to the state of delivery press the progr...

Page 8: ...st miswiring yes Polarity reversal protected yes Mechanical data Housing material PA Tightening torque 0 5 Nm Sensing face material PA Connection type Cable Cable jacket material PUR Cable diameter D...

Reviews: