71
deutsch
71
E
Service interface
RS 232
Read/Write Head*
integrated, BIS C-65_ and following;
option for mounted adapter BIS C-650*
2 x connectors 4-pin (male)
for all read/write heads BIS C-3_ _
with 4-pin connector (female),
not BIS C-350 and BIS C-352
option for mounted adapter BIS C-670*
1 x connector 8-pin (male) for
read/write heads BIS C-350 / BIS C-352
BIS operating states
LED red / green
Ready / Bus active
(LED in housing)
LED green / yellow
CT1 Present / Operating
LED green / yellow
CT2 Present / Operating
I
NTER
B
US
state
LED green
Reset
(LED on side
LED green
Cable Check
of housing)
LED green
Bus active
LED yellow
Remotebus Disable
Electrical
Connections
(continued)
BIS C-6001
Technical Data
Function Displays
* rotatable by 90°
The CE-Mark is your assurance that our products are in conformance with the
EC-Guideline
89/336/EEC (EMC-Guideline)
and the EMC Law. Testing in our EMC Laboratory, which is accredited by the DATech for
Testing of Electromagnetic Compatibility, has confirmed that Balluff products meet the
EMC requirements of the Generic Standard
EN 61000-6-4 (Emission) and EN 61000-4-2/3/4/5/6 (Noise Immunity).
C60_1-023_819395_0508_en.p65
72
72
E
Balluff Identification System
Type C Read/Write System
Hardware Type
6001 = I
NTER
B
US (remote bus)
Software Type
023 = I
NTER
B
US
Read/Write Head
000 = no read/write head
651 = with read/write head Type 651 (with circular antenna on top)
652 = with read/write head Type 652 (with circular antenna on front)
653 = with read/write head Type 653 (with rod antenna)
650 = with two connections for external read/write heads BIS C-3_ _
(except BIS C-350 and C-352)
670 = with offset connection for an external read/write head
BIS C-350 or BIS C-352
Interface
BUS versions
User Connection
KL2 Clamp connection via 1 x PG 9 and 2 x PG 11
Ordering Code
BIS C-6001
Ordering Information
BIS C-6001-023-_ _ _-03-KL2