Function Description
Parametering the BIS C-60_3 processor
DP2_Auto_Read
class:
64
Hex
instance: 01
Hex
attribute: 6C
Hex
Factory setting:
Disable
(= 0)
CT Present data, when the data carrier enters the read/write
zone of Head 2.
Other settings:
Enable
(= 1)
If the Auto Read function is enabled, data are read starting
from a specified start address as soon as a data carrier is
detected in front of Head 2.
For more information on the Auto Read function, see 44.
DP1_Start_Address
class:
64
Hex
instance: 01
Hex
attribute: 6D
Hex
Factory setting:
0
Other settings:
1...8191
This parameter sets the start address from which a data
carrier is read when a data carrier is detected in front of
Head 1.
For more information on the Auto Read function, see 44.
Parameter 9
Auto Read for
CT Present Head 2
Parameter 10
Start Address for
Auto Read Head 1
C60_3-025_825645_1310_e.p65
22
english
22
DP2_Start_Address
class:
64
Hex
instance: 01
Hex
attribute: 6E
Hex
Factory setting:
0
Other settings:
1...8191
This parameter sets the start address from which a data
carrier is read when a data carrier is detected in front of
Head 2.
For more information on the Auto Read function, see 44.
CRC_Check
class:
64
Hex
instance: 01
Hex
attribute: 6F
Hex
Factory setting:
Disable
(= 0)
Validity of the read data is ensured by double-reading.
Other settings:
Enable
(= 1)
Validity of the read data is ensured by calculating the CRC_16
on the read data and comparing with the CRC_16 stored on
the data carrier.
Parameter 11
Start Address for
Auto Read Head 2
Parameter 12
CRC
Function Description
Parametering the BIS C-60_3 processor