23
23
english
Parameter 13
Mode 2:
No. of bytes to
read Head 1
Input length 1
class:
65
Hex
instance: 01
Hex
attribute: 65
Hex
Factory setting:
31 Byte
Other settings:
2 Byte ....
(Buffer_Length – Input length 2 – 2) Byte
This setting specifies how many bytes should be read from
the data carrier in BIS Mode 2 on Head 1.
Please note when setting this parameter the explanation of
the in- and output buffers starting on 32.
Input address 1
class:
65
Hex
instance: 01
Hex
attribute: 66
Hex
Factory setting:
Start address 0
Other settings:
1 ... 8191
This setting specifies the starting address for reading data
carriers in BIS Mode 2 on Head 1.
☞
Function Description
Parametering the BIS C-60_3 processor
Parameter 14
Mode 2:
Start address for
reading, Head 1
C60_3-025_825645_1310_e.p65
24
english
24
Output length 1
class:
65
Hex
instance: 01
Hex
attribute: 68
Hex
Factory setting:
31 bytes
Other settings:
2 bytes ....
(Buffer_Length – Output length 2 – 2) bytes
This setting specifies how many bytes should be written to
the data carrier in BIS Mode 2 on Head 1.
Please note when setting this parameter the explanation of
the in- and output buffers starting on 32.
Output address 1
class:
65
Hex
instance: 01
Hex
attribute: 69
Hex
Factory setting:
Start address 0
Other settings:
1...8191
This setting specifies at which start address the data carrier
on Head 1 should be written to in BIS Mode 2.
Function Description
Parametering the BIS C-60_3 processor
Parameter 15
Mode 2:
No. of bytes for
writing Head 1
☞
Parameter 16
Mode 2:
Start address for
writing Head 1