www.balluff.com
Handheld Programmer
BIS U-870
13
Getting started
3
„Read ID“
submenu
Figure 7: „Configuration“ tab, „Read ID“ submenu
Display
Select the display mode. The display in the Read ID window can be either ASCII or hexadecimal.
Read ID Options
The following settings are possible:
Continuous
Reading:
Continuous reading. If this option is enabled, read requests are carried out
automatically at the set interval.
Beep:
Output an audio signal. If „Beep“ is activated, one of the following options
can be selected:
Detection:
–
If „Detection“ is activated, a signal sound is output following
each successful read.
Different Tag:
–
If „Different Tag“ is activated, a signal sound is output
following the first successful read.
Chrono
If this option is activated, the time for reading a defined number of different data carriers is output
(stopwatch function).
EPC Filter
If this option is selected and the
[SET]
button is clicked, the EPC filter in the Read-ID window is
used. The individual input fields have the following functions:
Mask:
Field of bytes in hexadecimal form
Mask Length:
Mask length in bits (not bytes)
Position:
Position at which the mask begins with its defined length
Example: EPC = „FF3804714277360000093188“, if the EPC filter with mask F380 is activated,
the mask length is 16 (16 bits = 2 bytes) and the position is 4 (1/2 byte), the Read ID operation
returns all data carriers with the following EPC code: „xF380xxxxxxxxxxxxxxxxxxx“.