BIS V-6107 TCP/IP, USB
Processor Unit
104
Read data carrier at read/write head 1, 2456 bytes USER data starting at Start address 0.
Application
BIS V
Command: Read data carrier, expanded
<ACK> [data]
<STX>
<ACK> [data]
<STX>
<EOT> [data]
Telegram example:
Control system
'H'
'0'
'0'
'0'
'0'
'0'
'0'
'0'
'0'
'2'
'4'
'5'
'6'
'1'
'R'
BCC
48
hex
30
hex
30
hex
30
hex
30
hex
30
hex
30
hex
30
hex
30
hex
32
hex
34
hex
35
hex
36
hex
31
hex
52
hex
2e
hex
Command
designator
Address of the first
byte to be read
Number of bytes
to be read
Read/write
head No. 1
Reserved
Example 1:
Read data
carrier,
expanded
9
Protocol