www.balluff.com
BIS V-6107 TCP/IP, USB
Processor unit
35
Various parameters can be used to affect the behavior of the identification system. A distinction
is made here between net parameters, device parameters, RFID parameters and IO-Link para-
meters. This section lists the individual parameters as well as their entry values (shown in italics)
and describes their function. The
underscored
entry values represent the factory default setting.
Note
Parameters are set using the configuration software
BIS Cockpit.
This is available
online at
www.balluff.com
. Information for using can be found in the manual for the
configuration software or the integrated help function.
Specifies the IPv4 address at which the processor unit can be accessed in the network.
e.g.
197.168.72.223
Specifies the subnet mask used for network communication.
e.g.
255.255.255.0
Specifies the IP address of the standard gateway (optional).
e.g.
192.168.72.254
Specifies the address mode.
Static:
The IP address defined with the parameter
IP address
is fixed.
DHCP:
The IP address is automatically assigned by a higher level DHCP server.
Note
When manually assigning the IP address be sure that the IP address and subnet
mask refer to the same subnet in which the network adapter and standard router are
connected to the processor unit.
Enable or disable entries using the display keys (security function).
Enabled/Disabled
Turns off/on all BIS V status LEDs (power-saving function).
Enabled/Disabled
Specifies how many TCP ports are used for the socket connection to the processor unit.
Single
/
Multi
(see next page
)
Note
Changes to the TCP Port Mode parameter only take effect after the processor unit is
restarted.
Note
If the connection is lost for more than 4 s while connected, the device is restarted.
8.1 Network
Parameter
IP-Address
Subnet mask
Standard-
Gateway
IP-Mode
8.2 Device
Parameter
Display read-
only
Device LEDs
TCP port Mode
8
Parameter Configuration
Summary of Contents for BIS V-6107